Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating
- 1 August 2003
- journal article
- cardiac
- Published by Springer Nature in European Radiology
- Vol. 13 (8) , 1923-1930
- https://doi.org/10.1007/s00330-003-1895-7
Abstract
The aim of this study was to reduce radiation exposure in multislice CT (MSCT) coronary artery calcium screening using different tube settings, and to determinate its impact on the detection and quantification of coronary artery calcification. Forty-eight patients underwent routine MSCT coronary artery calcium scoring (Somatom VolumeZoom, Siemens, Forchheim, Germany) with retrospective ECG-gated data acquisition. Scanning was performed with a 4×2.5-mm collimation. In each patient data acquisition was performed twice using tube settings of 120 kVp with 133 mAs (protocol 1) and of 80 kVp with 300 mAs (protocol 2). Together with the 80-kVp protocol additional online ECG-related tube current modulation (ECG pulsing) was used. Three-millimeter overlapping slices (increment 1.5 mm) were calculated for each data set. Semi-automated calcium quantification was performed calculating absolute Ca-hydroxylapatite mass. In addition to patient examinations, the radiation exposure for both protocols was evaluated using computed tomography dose index (CTDI) phantom measurements. Protocol 2 showed a significantly lower patient radiation exposure than protocol 1 (0.72 vs 2.04 mSv; pr=0.99; p<0.0001) for absolute Ca-Hydroxylapatite mass measurements. Using 80-kVp protocols patient radiation exposure can be significantly reduced in MSCT coronary artery calcium screening without affecting the detection and quantification of coronary artery calcification; therefore, this technique should be used with retrospective ECG-gated cardiac CT examinations in patients with regular sinus rhythm.Keywords
This publication has 17 references indexed in Scilit:
- Coronary artery calcium scoring: medicine and politicsEuropean Radiology, 2003
- Coronary Artery Calcium Measurement with Multi–Detector Row CT: In Vitro Assessment of Effect of Radiation DoseRadiology, 2002
- Coronary Artery Calcium MeasurementAmerican Journal of Roentgenology, 2001
- Technique Factors and Image Quality as Functions of Patient Weight at Abdominal CTRadiology, 2000
- Subsecond multi-slice computed tomography: basics and applicationsEuropean Journal of Radiology, 1999
- Contribution of trends in survival and coronar y-event rates to changes in coronary heart disease mortality: 10-year results from 37 WHO MONICA Project populationsThe Lancet, 1999
- Use of Electron-Beam Computed Tomography in the Evaluation of Chest Pain Patients in the Emergency DepartmentAnnals of Emergency Medicine, 1999
- Abschätzung der effektiven Dosis für Routineprotokolle beim konventionellen CT, Elektronenstrahl-CT und bei der KoronarangiographieRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1999
- Effect of HMG-CoA Reductase Inhibitors on Coronary Artery Disease as Assessed by Electron-Beam Computed TomographyNew England Journal of Medicine, 1998
- Coronary Artery Calcification: Pathophysiology, Epidemiology, Imaging Methods, and Clinical ImplicationsCirculation, 1996