Epidemiologic Assessment of Mortality, Building Collapse Pattern, and Medical Response after the 1992 Earthquake in Turkey
- 1 March 1997
- journal article
- research article
- Published by Cambridge University Press (CUP) in Prehospital and Disaster Medicine
- Vol. 12 (3) , 49-58
- https://doi.org/10.1017/s1049023x0003764x
Abstract
Background:: Post-earthquake engineering and epidemiologic assessments are important for the development of injury prevention strategies. This paper describes mortality and its relationship to building collapse patterns and initial medical responses following the 1992 earthquake in Erzincan, Turkey.Methods:: The study consisted of: 1) background data collection and review; 2) design and implementation of a field survey; and 3) site inspection of building collapse patterns. The survey included: 1) national (n = 11) and local (n = 17) officials; 2) medical and search and rescue (SAR) workers (n = 38); and 3) a geographically stratified random sample of lay survivors (n = 105). The survey instruments were designed to gather information regarding location, injuries, initial actions and prior training of survivors and responders, and the location, injuries, and management of dead and dying victims. A case-control design was constructed to assess the relationship between mortality, location, and building collapse pattern.Results:: There was extensive structural damage throughout the region, especially in the city where mid-rise, unreinforced masonry buildings (MUMBs) incorporating a “soft” first floor design (large store windows for commercial use) and one story adobe structures were most vulnerable to collapse. Of 526 people who died in the city, 87% (n = 456) were indoors at the time of the earthquake. Of these, 92% (n = 418) died in MUMBs. Of 54 witnessed deaths, 55% (n = 28) of victims died slowly, the majority of whom (n = 26) were pinned or trapped (p Conclusion:: During an earthquake, MUMBs with soft ground floor construction are highly lethal, especially for occupants on the ground floor, suggesting that this building type is inappropriate for areas of seismic risk. The vulnerability of MUMBs appears due to a lack of lateral force resistance as a result of the use of glass store fiont windows and the absence of shear walls. The prevalence of this building type in earthquake-prone regions needs to be investigated further. A large portion of victims dying in an earthquake die slowly at the scene of injury. Prior public first-aid and rescue training programs increase participation in rescue efforts in major earthquakes and may improve survival.Keywords
This publication has 19 references indexed in Scilit:
- A Medical Disaster Response to Reduce Immediate Mortality after an EarthquakeNew England Journal of Medicine, 1996
- Medical Section pf the American Lung Association: Guidelines for the Initial Management of Adults with Community-acquired Pneumonia: Diagnosis, Assessment of Severity, and Initial Antimicrobial TherapyAmerican Review of Respiratory Disease, 1993
- Organization and Management of Critical Care Systems in Unconventional SituationsCritical Care Clinics, 1993
- BuildingsEarthquake Spectra, 1991
- Forecasting Damaging Earthquakes in the Central and Eastern United StatesScience, 1990
- The 1988 earthquake in Soviet Armenia: A case studyAnnals of Emergency Medicine, 1990
- Socioeconomic Impacts and Emergency ResponseEarthquake Spectra, 1990
- Medical Support in the Tangshan EarthquakePublished by Wolters Kluwer Health ,1987
- Earthquake Injuries Related to Housing in a Guatemalan VillageScience, 1977
- ASSESSMENT OF COMA AND IMPAIRED CONSCIOUSNESSThe Lancet, 1974