Beating‐heart percutaneous mitral valve repair using a transcatheter endovascular suturing device in an animal model
- 23 February 2007
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 69 (4) , 525-531
- https://doi.org/10.1002/ccd.21029
Abstract
Background: The edge-to-edge (Alfieri) technique for mitral valve repair is a versatile method of treating mitral insufficiency. Because of its simplicity, it has been applied in minimally invasive surgery, and recently, in the design of endovascular closed-heart devices. Aim: The purpose of this study was to evaluate the acute in-vivo safety and feasibility of a novel percutaneous mitral valve repair system based on Alfieri technique in an animal model. Methods: Under general anesthesia, 11 pigs (90–100 kgs), underwent percutaneous Alfeiri procedure. The right femoral vein was punctured and the mitral valve was approached via a standard transeptal puncture. Combined intracardiac echo and fluoroscopic guidance was used. The procedure included: the positioning of a guide catheter for multiple access to the left atrium and for directing devices; the use of a therapy device to capture the free edge of the mitral valve leaflets using vacuum, and to deliver the suture to the valve and finally the fixation with a Nitinol suture clip, and trimming of the suture with a fastener catheter. Results: Leaflet capture, suture placement, and suture-clip deployment was successful in all 11 animals. There were no acute cardiac or access site complications. Procedural time (from wire in left atrium to completion of the procedure was 18 ± 9 min (range 9–30 min). Blood loss was 67 ± 44 ml (range 0–125ml). A double orifice configuration was visible by echocardiography at the end of the procedure in all animals. Conclusion: This acute animal study demonstrated the feasibility of a beating heart percutaneous Alfieri procedure in a non-diseased porcine valve using an endovascular suturing device to safely access the mitral valve, place a stitch through the mitral valve leaflets, and deploy a suture-clip that reproduces the surgical technique. Clinical application of this device in humans needs to be evaluated.Keywords
This publication has 12 references indexed in Scilit:
- Similar long-term results of mitral valve repair for anterior compared with posterior leaflet prolapseThe Journal of Thoracic and Cardiovascular Surgery, 2006
- Intracardiac Echocardiography for Percutaneous Mitral Valve Repair in a Swine ModelJournal of the American Society of Echocardiography, 2006
- Surgical Revision After Percutaneous Mitral Valve Repair With a Clip: Initial Multicenter ExperienceThe Annals of Thoracic Surgery, 2005
- Percutaneous Mitral Valve Repair Using the Edge-to-Edge Technique: Six-Month Results of the EVEREST Phase I Clinical TrialPublished by Elsevier ,2005
- Percutaneous Mitral Valve Repair for Chronic Ischemic Mitral RegurgitationCirculation, 2005
- Beating Heart Catheter-Based Edge-to-Edge Mitral Valve Procedure in a Porcine ModelCirculation, 2004
- Midterm results of edge-to-edge mitral valve repair without annuloplastyThe Journal of Thoracic and Cardiovascular Surgery, 2003
- Endovascular Edge-to-Edge Mitral Valve RepairCirculation, 2003
- Novel suture device for beating-heart mitral leaflet approximationThe Annals of Thoracic Surgery, 2002
- The double-orifice technique in mitral valve repair: A simple solution for complex problemsThe Journal of Thoracic and Cardiovascular Surgery, 2001