Digital Radiography Versus Conventional Radiography in Chest Imaging
- 1 January 2000
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 174 (1) , 75-80
- https://doi.org/10.2214/ajr.174.1.1740075
Abstract
OBJECTIVE. The objective of this study was to compare the diagnostic performance of a digital large-area silicon flat-panel detector with that of a conventional screen-film system in clinical chest imaging using abnormal findings documented by CT as the reference standard. SUBJECTS AND METHODS. Eighty patients (46 men and 34 women; age range, 18-91 years; mean age, 63 years) who underwent CT of the chest were examined with the new digital radiography system, which is based on a 43 × 43 cm silicon flat-panel detector, and with a conventional screen-film system, which is used routinely in clinical practice. Posteroanterior and lateral radiographs were obtained. Four radiologists analyzed the digital and conventional images separately for chest abnormalities and rated the images using a five-level scale of confidence; CT was used as the reference standard. Diagnostic value was assessed using receiver operating characteristic curves for each abnormality. RESULTS. No significant differences were found between the area under the receiver operating characteristic curve of the digital and that of the conventional radiography method for almost all investigated criteria. The only exception was mediastinal abnormalities, for which the digital method provided better results than the conventional method (p ≪0.05). CONCLUSION. The diagnostic performance of the new large-area silicon flat-panel detector is equivalent or superior to that of the conventional screen-film system for clinical chest imaging and can replace conventional radiography systems. This new technology offers transmission and storage possibilities inherent to digital radiology that would facilitate daily practice and reduce the initial high costs in the long-term.Keywords
This publication has 26 references indexed in Scilit:
- Comparison Between a Screen-Film System and a Selenium Radiography SystemInvestigative Radiology, 1999
- Clinical application of a flat-panel X-ray detector based on amorphous silicon technology: image quality and potential for radiation dose reduction in skeletal radiography.American Journal of Roentgenology, 1998
- Detection of Simulated Chest Lesions with Normal and Reduced Radiation DoseInvestigative Radiology, 1998
- Kann die digitale Selenradiographie in der Thoraxdiagnostik die analoge Röntgenaufnahmetechnik ersetzen?RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1997
- Observer performance in the localization of tubes and catheters on digital chest images: The role of expertise and image enhancementAcademic Radiology, 1996
- Selenium-based digital radiography of the chest: radiologists' preference compared with film-screen radiographs.American Journal of Roentgenology, 1995
- Digital chest radiography: Clinical aspectsJournal of Digital Imaging, 1995
- Technical advances in chest radiography.American Journal of Roentgenology, 1994
- Detection of bullous lung disease: conventional radiography vs digital storage phosphor radiography.American Journal of Roentgenology, 1991
- Some Practical Issues of Experimental Design and Data Analysis in Radiological ROC StudiesInvestigative Radiology, 1989