Spinal Cord Motoneuron Excitability during Isoflurane and Nitrous Oxide Anesthesia
Open Access
- 1 February 1997
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 86 (2) , 302-307
- https://doi.org/10.1097/00000542-199702000-00005
Abstract
Background: Recent evidence suggests that the spinal cord is an important site of anesthesia that is necessary for surgical immobility, but the specific effect of anesthetics within the spinal cord is unclear. This study assessed the effect of isoflurane and nitrous oxide on spinal motoneuron excitability by monitoring the H-reflex and the F wave. Methods: Eight adult patients, categorized as American Society of Anesthesiologists physical status 1 or 2, who were undergoing elective orthopaedic surgery were anesthetized with 0.6, 0.8, 1.0, and 1.2 times the estimated minimum alveolar concentration (MAC) of isoflurane. Nitrous oxide was added in graded concentrations of 30%, 50%, and 70%, whereas the isoflurane concentration was decreased to maintain a total MAC of 1. The H-reflex of the soleus muscle and the F wave of the abductor hallucis muscle were measured before anesthesia and 15 min after each change of anesthetic concentration. Four or more trials of the H-reflex and 18 trials of the F wave were recorded at each concentration of anesthesia. The effect of the anesthetics on the H-reflex and F wave was analyzed using. Dunnett's test. Results: H-reflex amplitude was decreased to 48.4 +/- 18.6% of preanesthesia level at 0.6 MAC isoflurane and to 33.8 +/- 19.1% when isoflurane concentration increased from 0.6 MAC to 1.2 MAC. F wave amplitude and persistence decreased to 52.2 +/- 33.6% and 44.4 +/- 26% of baseline at 0.6 MAC isoflurane, and to 33.8 +/- 26% and 21.7 +/- 22.8% at 1.2 MAC isoflurane. Isoflurane plus nitrous oxide (total 1 MAC) decreased H-reflex amplitude to 30.4-33.3% and decreased F wave persistence to 42.8-56.3% of baseline. Conclusions: Both isoflurane alone and isoflurane plus nitrous oxide decrease H-reflex and F-wave amplitude and F-wave persistence. These effects suggest that isoflurane and nitrous oxide decrease motoneuronal excitability in the human spinal cord. This may play an important role in producing surgical immobility.Keywords
This publication has 32 references indexed in Scilit:
- The Minimum Alveolar Concentration of Isoflurane in Patients Undergoing Bilateral Tubal Ligation in the Postpartum PeriodAnesthesiology, 1995
- Anesthetic Potency Is Not Altered after Hypothermic Spinal Cord Transection in RatsAnesthesiology, 1994
- Spinal and brain-stem SEPs and H reflex during enflurane anesthesiaElectroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 1994
- Anesthetic Potency (MAC) Is Independent of Forebrain Structures in the RatAnesthesiology, 1993
- F-wave normative studies in different nerves of healthy subjectsElectroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 1993
- The Hoffmann reflex: A means of assessing spinal reflex excitability and its descending control in manProgress in Neurobiology, 1987
- Determination and Applications of MACAnesthesiology, 1980
- The H-reflex as a Measure of Anesthetic Potency in ManAnesthesiology, 1969
- Minimum Alveolar Concentrations of Methoxyflurane, Halothane, Ether and Cyclopropane in ManAnesthesiology, 1967
- Minimum Alveolar Anesthetic ConcentrationAnesthesiology, 1965