Precision and reliability of strength (Jamar vs. Biodex handgrip) and body composition (dual-energy X-ray absorptiometry vs. bioimpedance analysis) measurements in advanced cancer patients
- 1 December 2008
- journal article
- research article
- Published by Canadian Science Publishing in Applied Physiology, Nutrition, and Metabolism
- Vol. 33 (6) , 1232-1239
- https://doi.org/10.1139/h08-122
Abstract
Important deteriorations in body composition and strength occur and need to be accurately measured in advanced cancer patients (ACPs). The aim of this study was to establish the relationship between a single-frequency bioimpedance analyzer (BIA) and the dual-energy X-ray absorptiometer (DXA), as well as the Jamar handgrip dynometer and the Biodex handgrip attachment, and to determine the precision of each of these instruments in ACPs. Eighty-one ACPs with non-small-cell lung cancer and gastrointestinal cancer were recruited from the McGill University Health Centre (Montreal, Que.). Consecutive paired measurements, with repositioning between measurements, were obtained for total-body DXA, BIA, Biodex handgrip, and BIA plus Jamar handgrip. The total-body percent coefficient of variation (%CV) for the BIA and DXA were 1.34 and 1.56 for fat mass (FM), respectively, and 0.42 and 0.72 for fat free mass (FFM), respectively. The %CV for the Jamar and Biodex handgrips were 6.3 and 16.7, respectively. Bland-Altman plots were used to characterize the limits of agreement between DXA and BIA for FM (4.60 +/- 7.80 (-3.19 to 12.39) kg) and FFM (-1.87 +/- 7.16 (-9.03 to 5.29) kg). Both DXA and BIA demonstrate good short-term precision in ACPs. However, given its poor accuracy, it remains to be determined if BIA can be used to monitor ACPs for changes in total-body tissue composition as a function of time, whether for observation or response to treatment. Furthermore, because of wide limits of agreement, the DXA and BIA cannot be used interchangeably in research or clinical settings. The Jamar handgrip dynamometer shows more consistency than the Biodex handgrip attachment in ACPs, and should therefore be the preferred measure of changes in strength over time.Keywords
This publication has 34 references indexed in Scilit:
- Body composition in underweight elderly subjects: reliability of bioelectrical impedance analysisClinical Nutrition, 2004
- Bedside methodsversusdual energy X‐ray absorptiometry for body composition measurement in COPDEuropean Respiratory Journal, 2002
- Validation of a leg-to-leg bioimpedance analysis system in assessing body composition in postmenopausal womenInternational Journal of Obesity, 1999
- Handgrip strength testing: A review of the literatureAustralian Occupational Therapy Journal, 1999
- Biology of CachexiaJNCI Journal of the National Cancer Institute, 1997
- Dual-energy X-ray absorptiometry and body compositionNutrition, 1996
- Detecting submaximal efforts in grip strength testing with the coefficient of variationJournal of Occupational Rehabilitation, 1993
- The relationship between wrist position, grasp size, and grip strengthThe Journal of Hand Surgery, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Evaluation of instruments for measuring grip strengthActa Orthopaedica, 1984