Correction of physiologically induced global off‐resonance effects in dynamic echo‐planar and spiral functional imaging
Top Cited Papers
Open Access
- 23 January 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 47 (2) , 344-353
- https://doi.org/10.1002/mrm.10065
Abstract
In functional magnetic resonance imaging, a rapid method such as echo‐planar (EPI) or spiral is used to collect a dynamic series of images. These techniques are sensitive to changes in resonance frequency which can arise from respiration and are more significant at high magnetic fields. To decrease the noise from respiration‐induced phase and frequency fluctuations, a simple correction of the “dynamic off‐resonance ink‐space” (DORK) was developed. The correction uses phase information from the center ofk‐space and a navigator echo and is illustrated with dynamic scans of single‐shot and segmented EPI and, for the first time, spiral imaging of the human brain at 7 T. Image noise in the respiratory spectrum was measured with an edge operator. The DORK correction significantly reduced respiration‐induced noise (image shift for EPI, blurring for spiral, ghosting for segmented acquisition). While spiral imaging was found to exhibit less noise than EPI before correction, the residual noise after the DORK correction was comparable. The correction is simple to apply and can correct for other sources of frequency drift and fluctuations in dynamic imaging. Magn Reson Med 47:344–353, 2002.Keywords
This publication has 29 references indexed in Scilit:
- IMPACT: Image‐based physiological artifacts estimation and correction technique for functional MRIMagnetic Resonance in Medicine, 2001
- Artifact due to B0 fluctuations in fMRI: Correction using the k‐space central lineMagnetic Resonance in Medicine, 2001
- Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR dataMagnetic Resonance in Medicine, 1996
- Compensation of multi‐dimensional selective excitation pulses using measured k‐space trajectoriesMagnetic Resonance in Medicine, 1995
- Spiral K‐space MR imaging of cortical activationJournal of Magnetic Resonance Imaging, 1995
- Reduction of signal fluctuation in functional MRI using navigator echoesMagnetic Resonance in Medicine, 1994
- Deblurring for non‐2D fourier transform magnetic resonance imagingMagnetic Resonance in Medicine, 1992
- Image reconstruction for echo planar imaging with nonequidistant k‐space samplingMagnetic Resonance in Medicine, 1992
- Selection of a convolution function for Fourier inversion using gridding (computerised tomography application)IEEE Transactions on Medical Imaging, 1991