Electrical impedance myography: Background, current state, and future directions
Top Cited Papers
- 18 September 2009
- journal article
- review article
- Published by Wiley in Muscle & Nerve
- Vol. 40 (6) , 936-946
- https://doi.org/10.1002/mus.21362
Abstract
Electrical impedance myography (EIM) is a non‐invasive technique for the evaluation of neuromuscular disease that relies upon the application and measurement of high‐frequency, low‐intensity electrical current. EIM assesses disease‐induced changes to the normal composition and architecture of muscle, including myocyte atrophy and loss, edema, reinnervation, and deposition of endomysial connective tissue and fat. With application of single‐frequency electrical current, EIM can be used to help grade the severity of neuromuscular disease. Assessing electrical impedance across a spectrum of applied frequencies and with current flow at multiple orientations relative to major muscle fiber direction can provide a more complete picture of the condition of muscle. EIM holds the promise of serving as an indicator of disease status. It may be useful in clinical trials and in monitoring effectiveness of treatment in individual patients; ultimately, it may also find diagnostic application. Ongoing efforts have been focused on obtaining a deeper understanding of the basic mechanisms of impedance change, studying EIM in a variety of clinical contexts, and further refining the methods of EIM data acquisition and analysis. Muscle Nerve, 2009Keywords
This publication has 41 references indexed in Scilit:
- Discriminating neurogenic from myopathic disease via measurement of muscle anisotropyMuscle & Nerve, 2008
- Reference values for 50‐kHZ electrical impedance myographyMuscle & Nerve, 2008
- Optimizing measurement of the electrical anisotropy of muscleMuscle & Nerve, 2008
- Impact of skin-subcutaneous fat layer thickness on electrical impedance myography measurements: An initial assessmentClinical Neurophysiology, 2007
- Electrical impedance myography to assess outcome in amyotrophic lateral sclerosis clinical trialsClinical Neurophysiology, 2007
- Neuromagnetic field strength outside the human head due to impedance changes from neuronal depolarizationPhysiological Measurement, 2004
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- The dielectric properties of biological tissues: I. Literature surveyPhysics in Medicine & Biology, 1996
- AAEM minimonograph #45: The early development of electromyographyMuscle & Nerve, 1995