Subattomole-Sensitivity Microchip Nanoelectrospray Source with Time-of-Flight Mass Spectrometry Detection
- 24 July 1999
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 71 (17) , 3627-3631
- https://doi.org/10.1021/ac990373m
Abstract
A microfabricated microfluidic device coupled with a nanospray tip for electrospray ionization of dilute solutions is described. The device has been interfaced with a time-of-flight mass spectrometer and evaluated for sensitive, high-speed detection of peptides and proteins. The electrospray voltage was applied through the microchip to the nanospray capillary that was attached at the end of a microfabricated channel. Fluid delivery rates were 20−30 nL min-1 through the hybridized structure without any pressure assistance. On-line microchip electrophoresis has been demonstrated and the effect of the capillary−chip junction on band broadening examined. Full mass spectra are acquired within 10−20 ms at 50−100 spectra s-1 storage rates. Detection of subattomole levels of sample from a 100 nM solution is demonstrated for infusion experiments.Keywords
This publication has 11 references indexed in Scilit:
- Microfabricated device coupled with an electrospray ionization quadrupole time-of-flight mass spectrometer: protein identifications based on enhanced-resolution mass spectrometry and tandem mass spectrometry dataRapid Communications in Mass Spectrometry, 1998
- InJectionadaptableFineIonizationSource (‘JaFIS’) for continuous flow nano-electrosprayRapid Communications in Mass Spectrometry, 1998
- Microdevices for Electrospray Mass SpectrometryPublished by Springer Nature ,1998
- A Microfabricated Device for Rapid Protein Identification by Microelectrospray Ion Trap Mass SpectrometryAnalytical Chemistry, 1997
- Generating Electrospray from Microchip Devices Using Electroosmotic PumpingAnalytical Chemistry, 1997
- Long-lived metallized tips for nanoliter electrospray mass spectrometryJournal of the American Society for Mass Spectrometry, 1996
- Attomole-Sensitivity Electrospray Source for Large-Molecule Mass SpectrometryAnalytical Chemistry, 1995
- Ultra-high-speed DNA fragment separations using microfabricated capillary array electrophoresis chips.Proceedings of the National Academy of Sciences, 1994
- Micro-Electrospray: Zeptomole/attomole per microliter sensitivity for peptidesJournal of the American Society for Mass Spectrometry, 1994
- Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a ChipScience, 1993