Wear, Debris, and Biologic Activity of Cross-linked Polyethylene in the Knee
- 1 November 2004
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 428 (428) , 114-119
- https://doi.org/10.1097/01.blo.0000148783.20469.4c
Abstract
Cross-linked polyethylene currently is being introduced in knee prostheses. The wear rates, wear debris, and biologic reactivity of non cross-linked, moderately cross-linked, and highly cross-linked polyethylene have been compared in multidirectional wear tests and knee simulators. Multidirectional pin-on-plate wear studies of noncross-linked, moderately cross-linked (5 Mrad), and highly cross-linked (10 Mrad) polyethylene showed a 75% reduction in wear with the highly cross-linked material under kinematics found in the hip, but only a 33% reduction under wear in kinematics representative of the knee. In knee simulator studies, with the fixed-bearing press-fit, condylar Sigma cruciate-retaining knee under high kinematic input conditions, the wear of 5 Mrad moderately cross-linked polyethylene was 13 ± 4 mm3 per 1 million cycles, which was lower (p < 0.05) than the wear of clinically used, gamma vacuum foil GUR 1020 polyethylene (23 ± 6 mm3/1 million cycles). For the low-contact stress mobile-bearing knee, the wear of moderately cross-linked polyethylene was 2 ± 1 mm3 per 1 million cycles, which was lower (p < 0.05) than GVF GUR 1020 polyethylene (5 ± 2 mm3/1 million cycles). The wear debris isolated from the fixed-bearing knees showed the moderately cross-linked material had a larger percentage volume of particles smaller than 1 μm in size, compared with GVF GUR 1020 polyethylene. Direct cell culture studies of wear debris generated in sterile wear simulators using multidirectional motion showed a increase (p < 0.05) in tumor necrosis factor-alpha levels and reactivity for GUR 1050 cross-linked polyethylene debris compared with an equivalent volume of noncross-linked GUR 1050 polyethylene. The use of cross-linked polyethylene in the knee reduces the volumetric wear rate. However, the clinical significance of reduced fracture toughness, elevated wear in abrasive conditions, and the elevated tumor necrosis factor-alpha release from smaller more reactive particles warrant further investigation.Keywords
This publication has 15 references indexed in Scilit:
- The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particlesBiomaterials, 2003
- Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trialThe Journal of Arthroplasty, 2003
- Polyethylene cross‐linking by two different methods reduces acetabular liner wear in a hip joint wear simulatorJournal of Orthopaedic Research, 2003
- Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prosthesesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2002
- Investigation of wear of knee prostheses in a new displacement/force-controlled simulatorProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2002
- A novel method for the prediction of functional biological activity of polyethylene wear debrisProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001
- Wear of fixed bearing and rotating platform mobile bearing knees subjected to high levels of internal and external tibial rotationJournal of Materials Science: Materials in Medicine, 2001
- Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implantsJournal of Biomedical Materials Research, 2001
- Properties of crosslinked ultra-high-molecular-weight polyethyleneBiomaterials, 2000
- Development of an extremely wear‐resistant ultra high molecular weight polythylene for total hip replacementsJournal of Orthopaedic Research, 1999