Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses
- 1 February 2002
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 216 (2) , 111-122
- https://doi.org/10.1243/0954411021536333
Abstract
The wear, wear debris and functional biological activity of non-crosslinked and moderately crosslinked ultrahigh molecular weight polyethylene (UHMWPE) acetabular cups have been compared when articulating against smooth and intentionally scratched femoral heads. Volumetric wear rates were determined in a hip joint simulator and the debris was isolated from the lubricant and characterized by the percentage number and volumetric concentration as a function of particle size. The volumetric concentration was integrated with the biological activity function determined from in vitro cell culture studies to predict an index of specific biological activity (SBA). The product of specific biological activity and volumetric wear rate was used to determine the index of functional biological activity (FBA). On smooth femoral heads the crosslinked UHMWPE had a 30 per cent lower wear rate, but it had a greater percentage volume of smaller, more biologically active particles, which resulted in a similar index of FBA compared with the non-crosslinked material. On the scratched femoral heads the volumetric wear rate was three times higher for the moderately crosslinked UHMWPE and two times higher for the non-crosslinked UHMWPE compared with the smooth femoral heads. This resulted in a higher wear rate for the moderately crosslinked material on the scratched femoral heads. All the differences in wear rate were statistically significant. There were only small differences in particle volume concentration distributions, and this resulted in similar indices of FBA which were approximately twice the values of those found on the smooth femoral heads. Both materials showed lower wear and FBA than for previously studied aged and oxidized UHMWPE gamma irradiated in air. However, this study did not reveal any advantage in terms of predicted FBA for moderately crosslinked UHMWPE compared with non-crosslinked UHMWPE.Keywords
This publication has 21 references indexed in Scilit:
- A novel method for the prediction of functional biological activity of polyethylene wear debrisProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001
- A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cupsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000
- Comparison of gas plasma and gamma irradiation in air sterilization on the delamination wear of the ultra-high molecular weight polyethylene used in knee replacementsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000
- Biological reactions to wear debris in total joint replacementProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000
- Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prosthesesJournal of Materials Science: Materials in Medicine, 2000
- A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and ratesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1999
- Comparative wear under four different tribological conditions of acetylene enhanced cross-linked ultra high molecular weight polyethyleneJournal of Materials Science: Materials in Medicine, 1999
- Mechanistic and Morphological Origins of Ultra-High Molecular Weight Polyethylene Wear Debris in Total Joint Replacement ProsthesesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1996
- Preliminary study of the effect of aging following irradiation on the wear of ultrahigh-molecular-weight polyethyleneThe Journal of Arthroplasty, 1995
- Isolation of predominantly submicron‐sized UHMWPE wear particles from periprosthetic tissuesJournal of Biomedical Materials Research, 1995