Bidirectional Ion Transfer between Quadrupole Arrays: MSn Ion/Ion Reaction Experiments on a Quadrupole/Time-of-Flight Tandem Mass Spectrometer
- 3 October 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (21) , 8199-8206
- https://doi.org/10.1021/ac071448m
Abstract
Methods for bidirectional ion transmission between distinct quadrupole arrays were developed on a quadrupole/time-of-flight tandem mass spectrometer (QqTOF) containing three quadrupoles (ion guide Q0, mass filter Q1, and collision cell Q2) and a reflectron TOF analyzer, for the purpose of implementing multistage ion/ion reaction experiments. The transfer efficiency, defined as the percentage of ions detected after two transfer steps relative to the initial ion abundance, was found to be about 60% between Q2 and Q0 (with passage through the intermediate array (Q1)) and almost 100% between Q2 and Q1. Efficient ion transfer enabled new means for executing MSn experiments on an instrument of this type by operating Q1 in rf/dc mode for performing multiple steps of precursor/product ion isolation while passing ions through Q1 or trapping ions in Q1. In the latter case, the Q1 functioned as a linear ion trap. Either collision induced dissociation (CID) or ion/ion reactions can be conducted in between each stage of mass analysis. MS3 or MS4 experiments were developed to illustrate the charge increase of peptide ions via two steps of charge inversion ion/ion reactions, CID of electron-transfer dissociation (ETD) products and CID of a metal−peptide complex formed from ion/ion reactions.Keywords
This publication has 23 references indexed in Scilit:
- Transmission Mode Ion/Ion Electron-Transfer Dissociation in a Linear Ion TrapAnalytical Chemistry, 2007
- Supplemental Activation Method for High-Efficiency Electron-Transfer Dissociation of Doubly Protonated Peptide PrecursorsAnalytical Chemistry, 2006
- Selective Disulfide Bond Cleavage in Gold(I) Cationized Polypeptide Ions Formed via Gas-Phase Ion/Ion Cation SwitchingJournal of Proteome Research, 2006
- Electron Transfer versus Proton Transfer in Gas-Phase Ion/Ion Reactions of Polyprotonated PeptidesJournal of the American Chemical Society, 2005
- Recent developments in the ion/ion chemistry of high‐mass multiply charged ionsMass Spectrometry Reviews, 2005
- Selective cation removal from gaseous polypeptide ions: proton vs. sodium ion abstraction via ion/ion reactionsPhysical Chemistry Chemical Physics, 2004
- MS3 using the collision cell of a tandem mass spectrometer systemRapid Communications in Mass Spectrometry, 2002
- Pulsed Gas Introduction for Increasing Peptide CID Efficiency in a MALDI/Quadrupole Ion Trap Mass SpectrometerAnalytical Chemistry, 1996
- Intrinsic interactions between alkaline earth metal ions and peptides: a gas-phase studyJournal of the American Chemical Society, 1990
- Consecutive reactions in triple analyzer mass spectrometry and applications to mixture analysisAnalytical Chemistry, 1982