Electrical conductivity imaging via contactless measurements
- 1 July 1999
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 18 (7) , 617-627
- https://doi.org/10.1109/42.790461
Abstract
A new imaging modality is introduced to image electrical conductivity of biological tissues via contactless measurements. This modality uses magnetic excitation to induce currents inside the body and measures the magnetic fields of the induced currents. In this study, the mathematical basis of the methodology is analyzed and numerical models are developed to simulate the imaging system. The induced currents are expressed using the A/spl I.oarr/-/spl phi/ formulation of the electric field where A/spl I.oarr/ is the magnetic vector potential and /spl phi/ is the scalar potential function. It is assumed that A/spl I.oarr/ describes the primary magnetic vector potential that exists in the absence of the body. This assumption considerably simplifies the solution of the secondary magnetic fields caused by induced currents. In order to solve /spl phi/ for objects of arbitrary conductivity distribution a three-dimensional (3-D) finite-element method (FEM) formulation is employed. A specific 7/spl times/7-coil system is assumed nearby the upper surface of a 10/spl times/10/spl times/5-cm conductive body. A sensitivity matrix, which relates the perturbation in measurements to the conductivity perturbations, is calculated. Singular-value decomposition of the sensitivity matrix shows various characteristics of the imaging system. Images are reconstructed using 500 voxels in the image domain, with truncated pseudoinverse. The noise level is assumed to produce a representative signal-to-noise ratio (SNR) of 80 dB. It is observed that it is possible to identify voxel perturbations (of volume 1 cm/sup 3/) at 2 cm depth. However, resolution gradually decreases for deeper conductivity perturbations.Keywords
This publication has 30 references indexed in Scilit:
- Differential characterization of neural sources with the bimodal truncated SVD pseudo-inverse for EEG and MEG measurementsIEEE Transactions on Biomedical Engineering, 1998
- Electrical impedance tomography: induced-current imaging achieved with a multiple coil systemIEEE Transactions on Biomedical Engineering, 1996
- A real-time electrical impedance tomography system for clinical use-design and preliminary resultsIEEE Transactions on Biomedical Engineering, 1995
- Imaging of cortical spreading depression by EIT: implications for localization of epileptic fociPhysiological Measurement, 1994
- Application of electrical impedance tomography to the determination of lung volumeClinical Physics and Physiological Measurement, 1992
- Detection of cortical spreading depression in the anaesthetised rat by impedance measurement with scalp electrodes: implications for non-invasive imaging of the brain with electrical impedance tomographyClinical Physics and Physiological Measurement, 1992
- Electrical impedance tomography of translationally uniform cylindrical objects with general cross-sectional boundariesIEEE Transactions on Medical Imaging, 1990
- Applications of applied potential tomography (APT) in respiratory medicineClinical Physics and Physiological Measurement, 1987
- Localisation of cardiac related impedance changes in the thoraxClinical Physics and Physiological Measurement, 1987
- SVD pseudoinversion image reconstructionIEEE Transactions on Acoustics, Speech, and Signal Processing, 1981