A Comparison of Minimum Inhibitory Concentration Values Determined by Three Antimicrobic Dilution Methods for Pseudomonas aeruginosa
Open Access
- 1 January 1981
- journal article
- research article
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 75 (1) , 39-44
- https://doi.org/10.1093/ajcp/75.1.39
Abstract
This investigation compares minimum inhibitory concentration measurements by three antimicrobic dilution methods for Pseudomonas aeruginosa versus seven antimicrobics. Minimum inhibitory concentrations were measured for 650 P. aeruginosa clinical isolates and for repeated tests with P. aeruginosa ATCC 27853 versus gentamicin, tobramycin, amikacin, netilmicin, sisomicin, carbenicillin, and ticarcillin, using the macro-broth, micro-broth, and agar dilution methods. For all antimicrobics,it was found that the micro-broth and agar dilution methods produced comparable minimum inhibitory concentration measurements, which were found to lie 1 to 2 double dilution steps below those determined by the macro-broth method. Acceptable replicability was found for both the macro-broth and the agar dilution methods. The micro-broth method showed less replicability, with 4.7% of minimum inhibitory concentration values lying ±2 or more double dilution steps from the modal value. It is important to recognize such differences if micro-broth or agar dilution methods are substituted for the macro-broth method.Keywords
This publication has 7 references indexed in Scilit:
- Evaluation of a Semiautomated Micro-broth Dilution System for Determining Minimum Inhibitory Concentrations of AntimicrobicsAmerican Journal of Clinical Pathology, 1980
- Cation Components of Mueller-Hinton Agar Affecting Testing of Pseudomonas aeruginosa Susceptibility to GentamicinAntimicrobial Agents and Chemotherapy, 1980
- Evaluation of the Moving Intermediate Zone Concept for Determining Susceptibility of Pseudomonads to Gentamicin by the Standardized Disk Agar-diffusion TestAmerican Journal of Clinical Pathology, 1979
- Effect of Different Lots of Mueller-Hinton Agar on the Interpretation of the Gentamicin Susceptibility of Pseudomonas aeruginosaAntimicrobial Agents and Chemotherapy, 1978
- Evaluation of a Dispensing Instrument (Dynatech MIC-2000) for Preparing Microtiter Antibiotic Plates and Testing Their Potency During StorageAntimicrobial Agents and Chemotherapy, 1978
- Evaluation of the Micro-Media System for Quantitative Antimicrobial Drug Susceptibility Testing: a Collaborative StudyAntimicrobial Agents and Chemotherapy, 1978
- Serial Dilution Antibiotic Sensitivity Testing with the Microtitrator SystemAmerican Journal of Clinical Pathology, 1966