A thin chip microsprayer system coupled to Fourier transform ion cyclotron resonance mass spectrometry for glycopeptide screening
- 4 November 2004
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 18 (23) , 2913-2920
- https://doi.org/10.1002/rcm.1705
Abstract
A thin polymer microchip was coupled with a Fourier transform ion cyclotron resonance (FTICR) 9.4 T mass spectrometer and the method was optimized in negative ion mode for glycopeptide screening. The interface between the polymer microchip and FTICR mass spectrometer consists of an in‐laboratory conceived and designed mounting system that exhibits robust and controllable alignment of the chip toward the inlet of the mass spectrometer. The particular attribute of the polymer chip coupled to the FTICR mass spectrometer, to achieve an increase in ionization efficiency and sensitivity under the premise of high mass accuracy of detection, is highlighted by the large number of major and minor glycopeptide structures detected and identified in highly heterogeneous mixtures obtained from urine matrices. Glycoforms expressing various saccharide chain lengths ranging from tri‐ to dodecasaccharide, bearing up to three sialic acid moieties, could be detected and assigned based on the accuracy of the mass measurement (average mass deviation below 6 ppm) of their molecular ions. (–)Thin chipESI‐FTICRMS is a potent novel system for glycomic screening of complex mixtures, as demonstrated for identification of singly sialylated O‐glycosylated amino acids and peptides from urine matrices, and could be considered for general applicability in the glycoanalytical field. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 36 references indexed in Scilit:
- Off-line capillary electrophoresis/fully automated nanoelectrospray chip quadrupole time-of-flight mass spectrometry and tandem mass spectrometry for glycoconjugate analysisJournal of Mass Spectrometry, 2004
- On‐line sheathless capillary electrophoresis/nanoelectrospray ionization‐tandem mass spectrometry for the analysis of glycosaminoglycan oligosaccharidesElectrophoresis, 2004
- Flow‐rate characterization of microfabricated polymer microspray emittersRapid Communications in Mass Spectrometry, 2004
- Plasma etched polymer microelectrochemical systemsLab on a Chip, 2002
- Microfabricated Devices for Capillary Electrophoresis−Electrospray Mass SpectrometryAnalytical Chemistry, 1999
- Generating Electrospray from Microchip Devices Using Electroosmotic PumpingAnalytical Chemistry, 1997
- Alpha-N-acetylgalactosaminidase deficiency with mild clinical manifestations and difficult biochemical diagnosisThe Journal of Pediatrics, 1994
- Isolation and Structural Characterization of Sialic Acid-Containing Glycopeptides of the O-GlycosidicType from the Urine of Two Patients with an Hereditary Deliciency in α-N-Acetylgalactosaminidase ActivityBiological Chemistry Hoppe-Seyler, 1989
- LYSOSOMAL α-N-ACETYLGALACTOSAMINIDASE DEFICIENCY: A NEW INHERITED METABOLIC DISEASEThe Lancet, 1987
- Space charge effects in Fourier transform mass spectrometry. II. Mass calibrationAnalytical Chemistry, 1984