Effects of a multifaceted, multidisciplinary, hospital-wide quality improvement program on weaning from mechanical ventilation
- 1 June 2002
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 30 (6) , 1224-1230
- https://doi.org/10.1097/00003246-200206000-00009
Abstract
To examine the effects of a mechanical ventilation weaning management protocol that was implemented as a hospital-wide, quality improvement program on clinical and economic outcomes. Prospective, before-and-after intervention study. Data from a preimplementation year are compared with those of the first 2 yrs after protocol implementation. Patients older than 18 yrs in diagnosis-related group 475 and group 483, who were admitted to the adult medical, surgical, and cardiac intensive care units (ICU) in a university hospital. After the baseline year, a weaning management program was implemented throughout our institution. Primary endpoints were mortality, days on mechanical ventilation, ICU and hospital lengths of stay, hospital costs, and the percentage of patients requiring tracheostomy. The number of patients increased from 220 in the baseline year (year 0) to 247 in the first year (year 1), then to 267 in the second year (year 2). The mean Acute Physiology and Chronic Health Evaluation (APACHE) II score increased from 22.2 to 24.4 in year 1 (p = .006) and to 26.2 in year 2 (p < .0005). When year 0 was compared with year 1, mean days on mechanical ventilation decreased from 23.9 to 21.9 days (p = .608), hospital length of stay decreased from 37.5 to 31.6 days (p = .058), ICU length of stay decreased from 30.5 to 25.9 days (p = .133), and total cost per case decreased from $92,933 to $78,624 (p = .061). When year 0 was compared with year 2, mean days on mechanical ventilation decreased from 23.9 days to 17.5 days (p = .004), mean hospital length of stay decreased from 37.5 to 24.7 days, mean ICU length of stay decreased from 30.5 to 20.3 days, total cost per case decreased from $92,933 to $63,687, and percentage of patients requiring tracheotomy decreased from 61% to 41% (all p < .0005). There was also a reduction in the percentage of patients requiring more than one course of mechanical ventilation during the hospitalization from 33% to 26% (p = .039), a total cost savings of $3,440,787 and a decrease in mortality between all 3 yrs from 32% to 28% (p = .062). A multifaceted, multidisciplinary weaning management program can change the process of care used for weaning patients from mechanical ventilation throughout an acute care hospital and across multiple services. This change can lead to large reductions in the duration of mechanical ventilation, length of stay, and hospital costs, even at a time when patients are sicker.Keywords
This publication has 16 references indexed in Scilit:
- Protocol Weaning of Mechanical Ventilation in Medical and Surgical Patients by RespiratoryCare Practitioners and NursesChest, 2000
- Large Scale Implementation of a Respiratory Therapist– driven Protocol for Ventilator WeaningAmerican Journal of Respiratory and Critical Care Medicine, 1999
- Decrease in ventilation time with a standardized weaning process.Archives of Surgery, 1998
- Effect of Failed Extubation on the Outcome of Mechanical VentilationChest, 1997
- Clinical and economic outcome of patients undergoing tracheostomy for prolonged mechanical ventilation in New York state during 1993Critical Care Medicine, 1997
- A randomized, controlled trial of protocol-directed versus physician-directed weaning from mechanical ventilationCritical Care Medicine, 1997
- Cost accounting of adult intensive careCritical Care Medicine, 1996
- The Prevalence of Nosocomial Infection in Intensive Care Units in EuropeJAMA, 1995
- Economics of Mechanical VentilationClinical Pulmonary Medicine, 1994
- Reduction of duration and cost of mechanical ventilation in an intensive care unit by use of a ventilatory management teamCritical Care Medicine, 1991