Carotid and vertebral artery blood flow in left‐ and right‐handed healthy subjects measured with MR velocity mapping
- 1 January 1994
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 4 (1) , 37-42
- https://doi.org/10.1002/jmri.1880040110
Abstract
The goal of the study was to establish normal carotid artery flow rates in left-handed and right-handed individuals as a standard against which patients with carotid artery disease could be compared. Antegrade and retrograde flow were measured in the ascending aorta, in the right and left common, internal, and external carotid arteries, and in the vertebral arteries of 12 healthy subjects. Five subjects were right-handed, five left-handed, and two ambidextrous. Measured flow rates were as follows: common carotid arteries, 360–557 mL/min (mean [± standard deviation], 465 mL/min ± 52); internal carotid arteries, 132–367 mL/min (mean, 265 mL/min ± 60); external carotid arteries, 113–309 mL/min (mean, 186 mL/min ± 51); vertebral arteries from 133–308 mL/min (mean, 244 mL/min ± 43); and cerebral circulation, 546–931 mL/min (mean, 774 mL/min ± 134). All right-handed subjects had higher flow rates in the left internal carotid artery than in the right, and all left-handed subjects had higher flow rates in the right internal carotid artery (P =.007). There were no significant differences in left and right common carotid artery flow rates between left- and right-handed subjects. The standard deviation of a single measurement was 5%. The flow rates were similar to those obtained previously with other techniques and could be used as a normal standard.Keywords
This publication has 25 references indexed in Scilit:
- Severity of aortic regurgitation: interstudy reproducibility of measurements with velocity-encoded cine MR imaging.Radiology, 1992
- Global left ventricular perfusion: noninvasive measurement with cine MR imaging and phase velocity mapping of coronary venous outflow.Radiology, 1992
- Determination of cerebral blood flow with a phase-contrast cine MR imaging technique: evaluation of normal subjects and patients with arteriovenous malformations.Radiology, 1992
- Middle cerebral artery: determination of flow velocities with MR angiography.Radiology, 1991
- Right and left lung perfusion: in vitro and in vivo validation with oblique-angle, velocity-encoded cine MR imaging.Radiology, 1991
- Right and left ventricular stroke volume measurements with velocity-encoded cine MR imaging: in vitro and in vivo validation.American Journal of Roentgenology, 1991
- Blood flow in the carotid arteries: quantification by using phase-sensitive MR imagingAmerican Journal of Roentgenology, 1989
- Quantitative Measurements of Cerebral Blood Flow Using SPECT and [99mTc]-d,l-HM-PAO Compared to Xenon-133Journal of Cerebral Blood Flow & Metabolism, 1988
- Electromagnetic studies on the blood flow through the carotid system in manNeurology, 1962
- Studies of the Cerebral Circulation with Labeled Erythrocytes in Healthy ManCirculation Research, 1961