Microbiologic Contamination of Peripheral Blood Stem Cell Autografts
- 1 July 1994
- journal article
- Published by Wiley in Vox Sanguinis
- Vol. 67 (1) , 32-35
- https://doi.org/10.1111/j.1423-0410.1994.tb05034.x
Abstract
We have determined the incidence and clinical significance of positive microbiologic cultures in a series of 290 peripheral blood stem cell concentrates in 95 patients undergoing multiple apheresis procedures for autologous stem cell rescue. Specimens for bacterial cultures were obtained after processing of the autografts just prior to freezing. The incidence of microbial contamination was 4.5% (n = 13). The predominant pathogenic microorganism cultured was coagulasenegative Staphylococcus (n = 11). From 8 patients with contaminated leukapheresis products 6 underwent autologous stem cell transplantation. Five patients received 1–5 culture‐positive stem cell concentrates without serious sequelae, whereas the sixth patient was autografted with noncontaminated leukapheresis products, 1 concentrate contaminated with Aspergillus fumigatus being not reinfused. No microorganism present in the stem cell autograft was recovered in vivo in the posttransplantation period, although fever as a sign of infection occurred in all but 1 patient. Peripheral blood stem cell collection and ex vivo processing for cryopreservation may result in microbiologic contamination. However, our data show that infusion of contaminated stem cell autografts does not play a significant role as a source for infections in the clinical setting of autologous stem cell rescue.Keywords
This publication has 12 references indexed in Scilit:
- Transfusion Reactions Due to Bacterial Contamination of Blood and Blood ProductsClinical Infectious Diseases, 1991
- Hematopoietic reconstitution using progenitors recovered from bloodTransfusion, 1989
- Autologous Bone Marrow TransplantationAnnals of Internal Medicine, 1989
- Bacterial contamination of bone marrow grafts intended for autologous and allogeneic bone marrow transplantationTransfusion, 1988
- Residual leukemia cannot be detected in very early remission peripheral blood stem cell collections in acute non-lymphoblastic leukemiaLeukemia Research, 1987
- Bacterial sepsis secondary to platelet transfusion: an adverse effect of extended storage at room temperatureTransfusion, 1986
- Escherichia coli sepsis from contaminated platelet transfusionArchives of internal medicine (1960), 1986
- The Fate of Bacteria Introduced into Whole Blood from Which Platelet Concentrates Were Prepared and Stored at 22 or 4 CTransfusion, 1975
- Bacteriocidal Properties of Platelet ConcentratesTransfusion, 1974
- Bacterial Contamination of Preserved BloodVox Sanguinis, 1959