Modeling for radio-frequency conductive keratoplasty: implications for the maximum temperature reached in the cornea
- 10 February 2005
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 26 (3) , 157-172
- https://doi.org/10.1088/0967-3334/26/3/002
Abstract
Conductive keratoplasty (CK) is a new surgical technique for steepening the contours of the cornea to reduce hyperopia. It has been emphasized that during CK, tissue resistance to radio-frequency electrical current flow generates a localized heat with temperatures between 65 and 75 degrees C; however, we hypothesize that the maximum temperature reached in the cornea may be higher. For this reason, we developed a finite-element model to estimate the temperature distributions in the cornea during CK. The time evolution of the impedance obtained from computer simulations was compared to that obtained in an experimental study previously published. Our results show that during a typical CK with a 60% setting power (equivalent to 200 V peak-to-peak), the cornea may reach temperatures over 100 degrees C at the electrode tip. On the other hand, the initial impedance of the cornea has a significant influence on the temperature distribution, while the initial temperature of the cornea is not a significant parameter. The results also suggest that low power settings (30-40%) do not produce temperatures over 100 degrees C. Finally, although the actual voltage waveform during CK is exponential and pulsed, our model based on a constant voltage (with a value equal to the root mean square value) provides a better agreement between the theoretical impedance time evolution and that obtained experimentally.Keywords
This publication has 26 references indexed in Scilit:
- Thermal-Electrical Modeling for Epicardial Atrial Radiofrequency AblationIEEE Transactions on Biomedical Engineering, 2004
- Laser in situ keratomileusis after conductive keratoplastyJournal of Cataract & Refractive Surgery, 2004
- Hepatic radiofrequency ablation with internally cooled probes: effect of coolant temperature on lesion sizeIEEE Transactions on Biomedical Engineering, 2003
- Semianalytical thermal model for subablative laser heating of homogeneous nonperfused biological tissue: application to laser thermokeratoplastyJournal of Biomedical Optics, 2003
- Dynamic impedance measurements during radio-frequency heating of corneaIEEE Transactions on Biomedical Engineering, 2002
- Radio-frequency heating of the cornea: theoretical model and in vitro experimentsIEEE Transactions on Biomedical Engineering, 2002
- A new catheter design using needle electrode for subendocardial RF ablation of ventricular muscles: finite element analysis and in vitro experimentsIEEE Transactions on Biomedical Engineering, 2000
- Comparison of In Vivo Tissue Temperature Profile and Lesion Geometry for Radiofrequency Ablation With a Saline-Irrigated Electrode Versus Temperature Control in a Canine Thigh Muscle PreparationCirculation, 1995
- The Effect of Electrode Design on the Efficiency of Delivery of Radiofrequency Energy to Cardiac Tissue In VitroPacing and Clinical Electrophysiology, 1989
- Shrinkage Temperature of Eye CollagenNature, 1964