Effects on torque angle curve of differences between the recorded tibia-calcaneal angle and the true anatomical angle
- 1 April 1981
- journal article
- research article
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 46 (1) , 41-46
- https://doi.org/10.1007/bf00422174
Abstract
The present study gives the results of a comparison of the recorded and true tibia-calcaneal angles in 17 normal subjects and in 14 patients with abnormally hypoextensible non contracting triceps. 1. For a minimal passive torque, the difference between true and recorded angles varied considerably from one individual to another. The means and ranges for the two groups were respectively: −8‡ (+7‡, −21‡) and −7‡ (+5‡, −20‡). 2. When the passive torque increased as a result of slow passive lengthening of the muscle, the true curve was steeper than the recorded one, owing to differences between the two angle measurements. For each of the two groups the differences in means and ranges were respectively: 6‡ (0‡, +13.5‡) and 8‡ (3‡, 12‡). 3. Subjects made isometric voluntary contractions of the triceps surae at fixed angles which corresponded to step by step muscle lengthening. The resulting true curve was much steeper than the recorded curve. The differences in means and ranges were: 7‡ (1.5‡, +15‡) in children of the two groups and respectively 3‡ (0‡, +9‡) and 12‡ (10‡, 14‡) in adults of the two groups. The present results show that this methodology was the only reliable way of correctly obtaining passive and active torque-angle curves, measuring differences between subjects, appreciating the effects of treatments and these by ascertaining whether or not trophic muscle regulation was defective.Keywords
This publication has 7 references indexed in Scilit:
- Trophic muscle regulation in children with congenital cerebral lesionsJournal of the Neurological Sciences, 1979
- Dependence of human ankle compliance on joint angleJournal of Biomechanics, 1978
- To what extent is the tibia-calcaneum angle a reliable measurement of the triceps surae length? Radiological correction of the torque-angle curve (III)European Journal of Applied Physiology, 1977
- Relationship of triceps surae torques to photographed tibia-calcaneum angles in man (II)European Journal of Applied Physiology, 1977
- An apparatus and a method for measuring the relationship of triceps surae torques to tibio-tarsal angles in manEuropean Journal of Applied Physiology, 1976
- Physiological and structural changes in the cat's soleus muscle due to immobilization at different lengths by plaster casts*The Journal of Physiology, 1972
- A ROTATIONAL JOINT APPARATUS - A DEVICE FOR STUDY OF TENSION-LENGTH RELATIONS OF HUMAN MUSCLE1967