Accelerating Monte Carlo simulations of radiation therapy dose distributions using wavelet threshold de-noising
- 30 September 2002
- journal article
- Published by Wiley in Medical Physics
- Vol. 29 (10) , 2366-2373
- https://doi.org/10.1118/1.1508112
Abstract
The Monte Carlo dose calculation method works by simulating individual energetic photons or electrons as they traverse a digital representation of the patient anatomy. However, Monte Carlo results fluctuate until a large number of particles are simulated. We propose wavelet threshold de-noising as a postprocessing step to accelerate convergence of Monte Carlo dose calculations. A sampled rough function (such as Monte Carlo noise) gives wavelet transform coefficients which are more nearly equal in amplitude than those of a sampled smooth function. Wavelet hard-threshold de-noising sets to zero those wavelet coefficients which fall below a threshold; the image is then reconstructed. We implemented the computationally efficient 9,7-biorthogonal filters in the C language. Transform results were averaged over transform origin selections to reduce artifacts. A method for selecting best threshold values is described. The algorithm requires about 336 floating point arithmetic operations per dose grid point. We applied wavelet threshold de-noising to two two-dimensional dose distributions: a dose distribution generated by 10 MeV electrons incident on a water phantom with a step-heterogeneity, and a slice from a lung heterogeneity phantom. Dose distributions were simulated using the Integrated Tiger Series Monte Carlo code. We studied threshold selection, resulting dose image smoothness, and resulting dose image accuracy as a function of the number of source particles. For both phantoms, with a suitable value of the threshold parameter, voxel-to-voxel noise was suppressed with little introduction of bias. The roughness of wavelet de-noised dose distributions (according to a Laplacian metric) was nearly independent of the number of source electrons, though the accuracy of the de-noised dose image improved with increasing numbers of source electrons. We conclude that wavelet shrinkage de-noising is a promising method for effectively accelerating Monte Carlo dose calculations by factors of 2 or more.Keywords
This publication has 7 references indexed in Scilit:
- Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planningPhysics in Medicine & Biology, 2000
- DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculationsPhysics in Medicine & Biology, 2000
- Denoising of electron beam Monte Carlo dose distributions using digital filtering techniquesPhysics in Medicine & Biology, 2000
- Clinical implementation of a Monte Carlo treatment planning systemMedical Physics, 1999
- Factoring wavelet transforms into lifting stepsJournal of Fourier Analysis and Applications, 1998
- 3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC)Medical Physics, 1996
- Unconditional Bases Are Optimal Bases for Data Compression and for Statistical EstimationApplied and Computational Harmonic Analysis, 1993