The manual hexadimethrine bromide (Polybrene) test
- 8 July 1987
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 27 (4) , 295-301
- https://doi.org/10.1046/j.1537-2995.1987.27487264734.x
Abstract
Serum proteins affect the performance of the manual hexadimethrine bromide (Polybrene) test. Red cells suspended in the low-ionic medium adhere to the surface of test tubes when centrifuged. This adherence is prevented by serum components apoprotein B, fibronectin, von Willebrand factor, or serum diluted less than 75-fold, but not by serum albumin or immunoglobulin fractions. A high concentration of serum reduces the sensitivity of the test and destabilizes antibody-dependent aggregation. Disaggregation time (DT), defined as the time required for antibody-dependent aggregates to disperse, was used as an indicator of agglutination stability. DT was often shortened when antibodies were in native serums, but could be prolonged if serums were diluted with 0.85 percent saline. Other factors that influenced DT included antibody concentration, temperature specificity, and sources of antibodies within specificities. When antibodies were present in a mixture, they produced various DTs related to individual specificities. Determination of these differences allowed the successful identification of multiple antibodies. The procedure, called differential disaggregation time, was also used for typing red cells coated by autoantibodies. Additional modifications improved the performance of the antiglobulin phase.This publication has 13 references indexed in Scilit:
- A proposal for compatibility testing incorporating the manual hexadimethrine bromide (Polybrene) testTransfusion, 1985
- Isolation and lipid-binding properties of rat apolipoprotein A-IVBiochimica et Biophysica Acta (BBA) - Lipids and Lipid Metabolism, 1985
- Quantitation of Antibody Binding to Erythrocytes in LISSVox Sanguinis, 1984
- Use of the manual Polybrene test in the routine hospital laboratoryTransfusion, 1983
- The Manual Polybrene Test: A Simple and Rapid Procedure for Detection of Red Cell AntibodiesTransfusion, 1980
- Augmentation of Hemagglutination by Low Ionic ConditionsTransfusion, 1979
- Human blood platelet adhesion to artery subendothelium is mediated by factor VIII–Von Willebrand factor bound to the subendotheliumNature, 1979
- Fibronectins—adhesive glycoproteins of cell surface and bloodNature, 1978
- Scoring of Hemagglutination ReactionsTransfusion, 1972
- A New Method for Detection of Red Blood Cell AntibodiesTransfusion, 1968