The perturbation of electron beam dose distributions at medium interfaces
- 1 November 1985
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 12 (6) , 754-763
- https://doi.org/10.1118/1.595660
Abstract
The perturbation of electron beam dose distributions in the vicinity of medium interfaces is calculated. Two different solutions to the Boltzmann equation, one an energy averaged solution and the other a diffusion approximation solution, are presented for the calculation of the electron distribution in the vicinity of interfaces. An extension of the energy averged formalism is presented for media with high atomic number. A new effective depth approximation is introduced to calculate the beam conditions beneath the interface. The transformation from electron distribution to dose distribution is made and dose calculations are compared with published electron beam dose measurements.Funding Information
- National Cancer Institute (CA-15548, CA-38180)
- DHHS
This publication has 5 references indexed in Scilit:
- A model for calculating electron beam scattering in treatment planningMedical Physics, 1982
- Backscattering in electron beam therapy for energies between 3 and 35 MeVPhysics in Medicine & Biology, 1982
- Lead shielding for electronsMedical Physics, 1981
- Dose enhancement from backscattered radiation at tissue–metal interfaces irradiated with high energy electronsThe British Journal of Radiology, 1980
- Field shaping in electron beam therapyThe British Journal of Radiology, 1976