Multicenter evaluation of the novel ABN Western blot (immunoblot) system in comparison with an enzyme-linked immunosorbent assay and a different Western blot
- 1 March 1992
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 30 (3) , 691-7
- https://doi.org/10.1128/jcm.30.3.691-697.1992
Abstract
A new, modular Western blot (immunoblot) system for human immunodeficiency virus (HIV) antibodies (ABN WesPage; Wellcome) was compared with enzyme immunoassays (Wellcome, Behringwerke, and Abbott) and with a U.S. Food and Drug Administration (FDA)-licensed Western blot (DuPont) in a multicenter study. A total of 649 serum samples from HIV patients at different stages of the disease, as well as from high-risk patients, from patients with conditions unrelated to AIDS, and from healthy blood donors, were used in the evaluation along with nine seroconversion panels. For evaluation of Western blot reactivity, both Centers for Disease Control (CDC) and FDA criteria were used. With the DuPont Western blot as the reference assay, the overall sensitivity and specificity of the ABN WesPage were 100 and 99.1%, respectively, when indeterminate results were not taken into account and when both tests were interpreted in accordance with CDC criteria. The DuPont Western blot detected significantly more antibodies to pol and gag gene products than the ABN WesPage. The ABN WesPage showed a higher positive rate of detection of viral envelope band gp160. When both Western blots were interpreted in accordance with CDC criteria, the ABN WesPage and the DuPont Western blot yielded 9.3 and 10.4% indeterminate results, respectively. When the DuPont Western blot was interpreted in accordance with the manufacturer's instructions (FDA criteria), 25.7% of the samples tested were regarded as indeterminate. The choice of interpretation criteria is of paramount importance for the evaluation of HIV Western blot patterns.Keywords
This publication has 16 references indexed in Scilit:
- Discrimination of HIV-2 Infection from HIV-1 Infection by Western Blot and Radioimmunoprecipitation AnalysisAIDS Research and Human Retroviruses, 1990
- Absence of HIV Infection in Blood Donors with Indeterminate Western Blot Tests for Antibody to HIV-1New England Journal of Medicine, 1990
- Current status of clinical laboratory tests for the human immunodeficiency virusJournal of Clinical Laboratory Analysis, 1990
- WHAT DO WESTERN BLOT INDETERMINATE PATTERNS FOR HUMAN IMMUNODEFICIENCY VIRUS MEAN IN EIA-NEGATIVE BLOOD DONORS?The Lancet, 1989
- Acute Human Immunodeficiency Virus Infection: False-Negative ELISA in a Patient with Viremia and a Positive Western Blot TestThe Journal of Infectious Diseases, 1989
- HLA Antigen Contamination of Commercial Western Blot Strips for Detecting Human Immunodeficiency VirusThe Journal of Infectious Diseases, 1989
- Evaluation of atypical human immunodeficiency virus immunoblot reactivity in blood donorsTransfusion, 1988
- HTLV-V: a New Human Retrovirus Isolated in a Tac-Negative T Cell Lymphoma/LeukemiaScience, 1987
- Studies of human retroviruses in relation to adult T-cell leukaemia, acquired immune deficiency syndrome, and multiple sclerosisArchiv für die gesamte Virusforschung, 1987
- LONG LATENCY PRECEDES OVERT SEROCONVERSION IN SEXUALLY TRANSMITTED HUMAN-IMMUNODEFICIENCY-VIRUS INFECTIONThe Lancet, 1987