In vitro mechanical and biological assessment of hydroxyapatite-reinforced polyethylene composite
- 1 January 1997
- journal article
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 8 (12) , 775-779
- https://doi.org/10.1023/a:1018516813604
Abstract
In vitro performance of hydroxyapatite (HA)-reinforced polyethylene (PE) composite (HAPEX) has been characterized from both mechanical and biological aspects. The mechanical properties of HAPEX, such as tensile strength and Young's modulus, showed little change after immersion in a physiological solution at 37 and 70 degrees C for various periods. In addition, the biological response of primary human osteoblast-like (HOB) cells in vitro on HAPEX was assessed by measuring DNA synthesis and osteoblast phenotype expression. Cell proliferation rate on HAPEX was demonstrated by an increase in DNA content with time. A high tritiated thymidine ([3H]-TdR) incorporation/DNA rate was observed on day 1 for HAPEX, indicating a stimulatory effect on cell proliferation. The alkaline phosphatase (ALP) activity was expressed earlier on HAPEX than on unfilled PE and increased with time, indicating that HOB cells had commenced differentiation. Furthermore, it was found that the HA particles in the composite provided favourable sites for cell attachment. It appears that the presence of HA particles in HAPEX may have the advantage of acting as microanchors for bone bonding in vivo.Keywords
This publication has 7 references indexed in Scilit:
- Histological and biochemical evaluation of osteoblasts cultured on bioactive glass, hydroxylapatite, titanium alloy, and stainless steelJournal of Biomedical Materials Research, 1993
- DNA fluorometric assay in 96-well tissue culture plates using Hoechst 33258 after cell lysis by freezing in distilled waterAnalytical Biochemistry, 1990
- Solutions able to reproduce in vivo surface‐structure changes in bioactive glass‐ceramic A‐W3Journal of Biomedical Materials Research, 1990
- Preliminary studies on the phenomenological behaviour of osteoblasts cultured on hydroxyapatite ceramicsBiomaterials, 1990
- A model for biocompatibility and its evaluationJournal of Biomedical Engineering, 1989
- Development of a new system for evaluating the biocompatibility of implant materials using an osteogenic cell line (MC3T3‐E1)Journal of Biomedical Materials Research, 1988
- Hydroxyapatite reinforced polyethylene — a mechanically compatible implant material for bone replacementBiomaterials, 1981