The mechanical and morphological properties of bone beneath internal fixation plates of differing rigidity
- 1 March 1989
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 7 (2) , 170-177
- https://doi.org/10.1002/jor.1100070203
Abstract
The internal fixation of diaphyseal fractures by bone plates is a well recognized treatment. The normal physiological stress of bone is reduced by plates that cause a negative balance of bone‐remodeling processes. Many investigators have shown that the degree of stress protection is dependent on the rigidity of the plates. It was the aim of this study to quantify mechanical and morphological changes at different locations in a plated diaphyseal bone as a function of differing plate rigidity. Two types of plates with the same size but different materials were used. The stainless steel plates had a modulus of elasticity and bending stiffness 3.2 times higher than the carbon fiber reinforced carbon plates. Both types of plates were applied to the intact right and left femora of six foxhounds for 6 months. The stiffer stainless steel plates led to a significantly higher bone loss and correspondingly greater loss of mechanical properties. These effects were greatest directly beneath the plate and less with increasing distance from the plate.Keywords
This publication has 18 references indexed in Scilit:
- Bone Loss in Plated Shaft Bone — A Parametric StudyPublished by Springer Nature ,1985
- The Stress-Protecting Effect of Metal Plates on the Intact Rabbit TibiaActa Orthopaedica, 1983
- Less rigid internal fixation plates: Historical perspectives and new conceptsJournal of Orthopaedic Research, 1983
- Biomechanical and Mathematical Investigations Concerning Stress Protection of Bone Beneath Internal Fixation PlatesPublished by Springer Nature ,1982
- The Influence of Immobilization on the Mechanical and Morphological Properties of BonePublished by Springer Nature ,1982
- Experimentelle Untersuchungen zum Einfluß des Plattenmaterials auf die Entlastung und Atrophie des Knochens unter Osteosyntheseplatten - Experimental Studies on the Influence of Plate Material on Stress-Relief and Atrophy of the Bone beneath Osteosynthesis PlatesBiomedizinische Technik/Biomedical Engineering, 1981
- A comparison of cortical bone atrophy secondary to fixation with plates with large differences in bending stiffnessJournal of Bone and Joint Surgery, 1976
- Quantitative histological evaluation of early fracture healing of cortical bones immobilized by stainless steel and composite platesCalcified Tissue International, 1975
- Veränderungen mechanischer Qualität der unter Druckplatten liegenden Knochencorticalis (Stressprotection)Published by Springer Nature ,1974
- Bone Structure Changes in the Dog Under Rigid Internal FixationClinical Orthopaedics and Related Research, 1971