The Stress-Protecting Effect of Metal Plates on the Intact Rabbit Tibia
Open Access
- 1 January 1983
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 54 (6) , 810-818
- https://doi.org/10.3109/17453678308992914
Abstract
The purpose of the present study was to find the extent of stress-protection by a steel plate (45 × 5 × 1 mm) on the rabbit tibia. The animals were sacrificed after 6, 12 and 18 weeks. The median strength after plate application was 84, 73 and 72%, respectively. The elastic stiffness of plated bones was also reduced, while the deformation at fracture showed no significant reduction. The mineral content in the bone segment previously covered by a plate was measured by photon absorptiometry; it was reduced after 12 and 18 weeks. The stress-protecting effect caused by this thin steel plate was less pronounced than that previously reported by groups using more rigid plates on rabbit tibiae. The stress-protecting effect increased up to 12 weeks, but subsequently no further increase occurred.Keywords
This publication has 24 references indexed in Scilit:
- A quantitative assessment of compression plate fixation in vivo: An experimental study using the sheep radiusJournal of Biomechanics, 1981
- Experimentelle Untersuchungen zum Einfluß des Plattenmaterials auf die Entlastung und Atrophie des Knochens unter Osteosyntheseplatten - Experimental Studies on the Influence of Plate Material on Stress-Relief and Atrophy of the Bone beneath Osteosynthesis PlatesBiomedizinische Technik/Biomedical Engineering, 1981
- Recovery of Diaphyseal Bone Strength After Rigid Internal Plate Fixation:An Experimental Study in the RabbitActa Orthopaedica, 1980
- The comparison of steel and titanium dynamic compression plates used for internal fixation of 256 fractures of the tibiaInjury, 1979
- Atrophy of Cortical Bone Caused by Rigid Internal Fixation Plates:An Experimental Study in the DogActa Orthopaedica, 1978
- Studies on Mechanical Strength of Bone:I. Torsional Strength of Normal Rabbit Tibio-Fibular BoneActa Orthopaedica, 1978
- Studies on Mechanical Strength of Bone: II.Torsional Strength of Cortical Bone after Rigid Plate Fixation with and without CompressionActa Orthopaedica, 1978
- The Effects of Rigidity of Internal Fixation Plates on Long Bone Remodeling:A Bio Mechanical and Quantitative Histological StudyActa Orthopaedica, 1976
- Untersuchungen zum Verhalten der Mikrostruktur der menschlichen Corticalis nach DruckplattenosteosyntheseArchives of orthopaedic and trauma surgery, 1975
- Measurement of Bone Mineral in vivo: An Improved MethodScience, 1963