Development of a Fluorescence Polarization Immunoassay for Lorazepam Quantification
- 1 April 1996
- journal article
- research article
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 18 (2) , 194-199
- https://doi.org/10.1097/00007691-199604000-00014
Abstract
Summary Lorazepam concentrations have been quantified in biological fluids using gas chromatography and high-performance liquid chromatography (HPLC). However, these methods are too time consuming and labor intensive for most nonresearch laboratories to offer. A fluorescence polarization immunoassay (FPIA) method for quantification of lorazepam was developed and validated using a reverse-phase HPLC method as the reference method. The FPIA method involves a single liquid-liquid extraction of 100 μl of either serum or plasma, then direct analysis using the TDxFLx (Abbott Diagnostics, North Chicago, IL). FPIA calibrations were linear between 50 and 800 ng/ml using five calibrators prepared in human serum. Within-run precision (n = 10) for three serum controls (75, 300, and 600 ng/ml) resulted in coefficients of variation (CVs) of 5.7%, 5.4%, and 4.2%, respectively. Between-day precision studies for the three serum controls were 7.0%, 8.9% and 4.9%, respectively (n = 5). The analytical recovery of the three serum controls was 104.9%, 97.3% and 98.3%, respectively. There was an excellent linear correlation between the FPIA and HPLC determinations of 43 patient specimens (r = 0.990, slope = 0.961, intercept = 16.3). No interferences were found from many commonly prescribed nonbenzodiazepine drugs; however, other benzodiazepines that were tested will cross-react with this procedure and give inaccurate results. Therefore, this method should not be used in patients who are receiving other benzodiazepines in addition to lorazepam. The FPIA method described herein can be adapted to reliably measure lorazepam concentrations in serum or plasma.Keywords
This publication has 17 references indexed in Scilit:
- Pediatric Analgesia and SedationAnnals of Emergency Medicine, 1994
- A Method for Rapid Determination of Lorazepam by High-Performance Liquid ChromatographyTherapeutic Drug Monitoring, 1993
- Determination of Lorazepam in Plasma of Patients during Status Epilepticus by High-Performance Liquid ChromatographyTherapeutic Drug Monitoring, 1988
- Lorazepam analysis using liquid chromatography: improved sensitivity for single-dose pharmacokinetic studiesJournal of Chromatography B: Biomedical Sciences and Applications, 1986
- Double-blind study of lorazepam and diazepam in status epilepticusJAMA, 1983
- PLASMA CONCENTRATIONS AND CLINICAL EFFECTS OF LORAZEPAM AFTER ORAL ADMINISTRATIONBritish Journal of Anaesthesia, 1981
- Analysis of lorazepam and its glucoronide metabolite by electron-capture gas—liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1978
- Book ReviewTextbook of Adverse Drug ReactionsNew England Journal of Medicine, 1978
- METABOLISM OF LORAZEPAMBritish Journal of Anaesthesia, 1976
- Determination of lorazepam in plasma by electron capture GLCArchives of Toxicology, 1976