Molar substitution and C2/C6 ratio of hydroxyethyl starch: influence on blood coagulation
Open Access
- 7 February 2006
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 96 (4) , 455-463
- https://doi.org/10.1093/bja/ael019
Abstract
Background. Development of hydroxyethyl starches (HES) with a low impact on blood coagulation but a long intravascular persistence is of clinical interest. A previous in vitro study showed that low substituted high molecular weight HES does not compromise blood coagulation more than medium molecular weight HES. In the present study we assessed the individual effects on blood coagulation of molar substitution and C2/C6 ratio of a high molecular weight HES. Methods. Blood was obtained from 30 healthy patients undergoing elective surgery and mixed with six high molecular weight (700 kDa) HES solutions differing in their molar substitution (0.42 and 0.51) and C2/C6 ratio (2.7, 7 and 14) to achieve 20, 40 and 60% dilution. Blood coagulation was assessed by Thrombelastograph® analysis (TEG) and plasma coagulation tests.Data were compared using a three-way analysis of variance model with repeated measures on the three factors. Results. Higher molar substitution compromised blood coagulation most (for all TEG parameters, Pr (PP=0.003) and coagulation index (P0.50). The higher molar substitution was associated with a lesser increase in PT (P=0.007) and a greater decrease in factor VIII (P=0.010). PTT, functional and antigenic von Willebrand factors were not significantly influenced by molar substitution (P for all >0.20). No significant differences between solutions with the same molar substitution but different C2/C6 ratios were found in plasma coagulation parameters (P for all >0.05). Conclusions. TEG analysis indicates that high molecular HES with a molar substitution of 0.42 and a C2/C6 ratio of 2.7 has the lowest effect on in vitro human blood coagulation.Keywords
This publication has 18 references indexed in Scilit:
- Thromboelastography Maximum Amplitude Predicts Postoperative Thrombotic Complications Including Myocardial InfarctionAnesthesia & Analgesia, 2005
- Artificial colloids impair haemostasis. An in vitro study using thromboelastometry coagulation analysisActa Anaesthesiologica Scandinavica, 2005
- Evidence-based Colloid Use in the Critically IllAmerican Journal of Respiratory and Critical Care Medicine, 2004
- New Light on Intravascular Volume Replacement Regimens: What Did We Learn from the Past Three Years?Anesthesia & Analgesia, 2003
- Binding of Hydroxyethyl Starch Molecules to the Platelet SurfaceAnesthesia & Analgesia, 2003
- Thromboelastography: Another Point of ViewAnesthesia & Analgesia, 2001
- Low- and Medium-molecular-weight Hydroxyethyl StarchesAnesthesiology, 2000
- Citrate Storage Affects Thrombelastograph®AnalysisAnesthesiology, 2000
- In Vitro Effects of Different Medium Molecular Hydroxyethyl Starch Solutions and Lactated Ringer’s Solution on Coagulation Using SONOCLOTAnesthesia & Analgesia, 2000
- All medium starches are not the same: Influence of the degree of hydroxyethyl substitution of hydroxyethyl starch on plasma volume, hemorrheologic conditions, and coagulationTransfusion, 1996