An analysis of MCNP cross-sections and tally methods for low-energy photon emitters
- 5 April 2002
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 47 (8) , 1321-1332
- https://doi.org/10.1088/0031-9155/47/8/307
Abstract
Monte Carlo calculations are frequently used to analyse a variety of radiological science applications using low-energy (10–1000 keV) photon sources. This study seeks to create a low-energy benchmark for the MCNP Monte Carlo code by simulating the absolute dose rate in water and the air-kerma rate for monoenergetic point sources with energies between 10 keV and 1 MeV. The analysis compares four cross-section datasets as well as the tally method for collision kerma versus absorbed dose. The total photon attenuation coefficient cross-section for low atomic number elements has changed significantly as cross-section data have changed between 1967 and 1989. Differences of up to 10% are observed in the photoelectric cross-section for water at 30 keV between the standard MCNP cross-section dataset (DLC-200) and the most recent XCOM/NIST tabulation. At 30 keV, the absolute dose rate in water at 1.0 cm from the source increases by 7.8% after replacing the DLC-200 photoelectric cross-sections for water with those from the XCOM/NIST tabulation. The differences in the absolute dose rate are analysed when calculated with either the MCNP absorbed dose tally or the collision kerma tally. Significant differences between the collision kerma tally and the absorbed dose tally can occur when using the DLC-200 attenuation coefficients in conjunction with a modern tabulation of mass energy-absorption coefficients.Keywords
This publication has 18 references indexed in Scilit:
- Photon mass attenuation and energy-absorption coefficientsPublished by Elsevier ,2002
- Radial dose distribution, dose to water and dose rate constant for monoenergetic photon point sources from 10 keV to 2 MeV: EGS4 Monte Carlo model calculationMedical Physics, 1999
- Fetal dose assessment from invasive special procedures by Monte Carlo methodsMedical Physics, 1999
- Calculated dosimetric parameters of the IoGold 125I source model 3631‐AMedical Physics, 1998
- Monte Carlo simulation in SPECT: complete 3D modeling of source, collimator and tomographic data acquisitionIEEE Transactions on Nuclear Science, 1993
- Photon cross sections from 1 keV to 100 MeV for elements Z=1 to Z=100Atomic Data and Nuclear Data Tables, 1970
- X-ray scattering factors computed from numerical Hartree–Fock wave functionsActa Crystallographica Section A, 1968
- -,-, and-Shell Atomic Photoeffect for Screened-Potential ModelsPhysical Review B, 1967
- Atomic Photoeffect in the RangekeVPhysical Review B, 1967