Hemodynamic Assessment of Right, Left, and Biventricular Pacing by Peak Endocardial Acceleration and Echocardiography in Patients with End‐Stage Heart Failure
- 1 November 2000
- journal article
- clinical trial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 23 (11P2) , 1726-1730
- https://doi.org/10.1111/j.1540-8159.2000.tb07005.x
Abstract
Multisite ventricular pacing acutely improves the hemodynamic status in heart failure, though longer‐term observations require invasive procedures. The hemodynamics of multisite ventricular pacing were assessed by echocardiography and peak endocardial acceleration (PEA) measured by a pacemaker sensor. PEA variations are highly correlated with those of dP/dt. Thirteen end‐stage heart failure patients (left ventricular ejection fraction < 0.30) with a QRS ≤140 ms received a DDD PEA sensor‐driven pacemaker allowing right (RV), left (LV) and biventricular (BV) pacing. Ten days after implantation, standard echocardiographic parameters and variations in PEA were measured after 20 minutes at each pacing mode. The aortic systolic preejection time interval was statistically comparable between RV and LV pacing (218 ± 24 vs 219 ± 34 ms; P = NS), and significantly shorter with BV pacing (198 ± 27 ms; P = 0.013). Aortic ejection duration was nonsignificantly shorter during BV pacing than during LV pacing (‐.061, P = 0.09). The aortic velocity time integer increased during LV pacing versus RV pacing (+21 %, P < 0.05) and during BV pacing versus RV pacing (+37%, P = 0.05). As a result, the values of the PEA variations over a 15‐minute period were significantly greater during LV pacing and BV pacing versus RV pacing (+43%, P < 0.05, and +38%, P = 0.05, respectively) and were statistically comparable between BV pacing and LV pacing (+5.9% for LV pacing, P = NS). During various ventricular pacing configurations, PEA measurements were consistent with echocardiographic data, showing comparable hemodynamic effects of BV and LV pacing. The PEA sensor is a promising tool for long‐term hemodynamic monitoring and serial evaluation of the effects of multisite ventricular pacing in heart failure patients.Keywords
This publication has 13 references indexed in Scilit:
- Electrocardiographic predictive factors of long-term clinical improvement with multisite biventricular pacing in advanced heart failureThe American Journal of Cardiology, 1999
- Improved Left Ventricular Mechanics From Acute VDD Pacing in Patients With Dilated Cardiomyopathy and Ventricular Conduction DelayCirculation, 1999
- Pacing therapy for congestive heart failure: Is it ready for prime time?Current Opinion in Cardiology, 1999
- Evaluation of Different Ventricular Pacing Sites in Patients With Severe Heart FailureCirculation, 1997
- An Implantable Intracardiac Accelerometer for Monitoring Myocardial ContractilityPacing and Clinical Electrophysiology, 1996
- Multisite Pacing for End‐Stage Heart Failure: Early ExperiencePacing and Clinical Electrophysiology, 1996
- Natural history of abnormal conduction and its relation to prognosis in patients with dilated cardiomyopathyInternational Journal of Cardiology, 1996
- Nature of ventricular activation in patients with dilated cardiomyopathy: evidence for bilateral bundle branch block.Heart, 1994
- Effect of left bundle branch block on diastolic function in dilated cardiomyopathy.Heart, 1991
- Serial electrocardiographic changes in idiopathic dilated cardiomyopathy confirmed at necropsyThe American Journal of Cardiology, 1988