Abstract
Morphologic observations suggest that the inner layers of the thoracic aorta in man and dog are avascular and the outer layers have vasa vasorum. It appears that vasa vasorum are essential in the thoracic aorta because their interruption produces medial necrosis. These experiments provide the first measurements of blood flow through aortic vasa vasorum and examine physiologic regulation of that flow. During control conditions the outer two-thirds of the media of the thoracic aorta received 10 ml/min per 100 g blood flow through vasa vasorum. Flow to the inner third of the aorta was 1 ml/min per 100 g. Flow to both the inner and outer media of the abdominal aorta was less than 1 ml/min per 100 g. Adenosine increased blood flow to vasa vasorum in the outer media of the thoracic aorta from 7 to 18 ml/min per 100 g, but did not increase flow to the inner layers of the aorta. Hemorrhagic hypotension decreased flow in the outer media of the thoracic aorta from 14 to 2 ml/min per 100 g. Acute hypertension failed to increase blood flow through vasa vasorum, as conductance decreased significantly. These studies indicate that vasa vasorum provide a considerable amount of blood flow to the outer layers of the thoracic aorta. The vessels are responsive to physiologic stimuli because they dilate during infusion of adenosine and constrict during both hemorrhagic hypotension and acute hypertension. We speculate that the failure of blood flow to the aortic wall to increase during acute hypertension might, if it were sustained, contribute to aortic medial necrosis.Keywords
This publication has 13 references indexed in Scilit:
- Blood flow measurements with radionuclide-labeled particlesProgress in Cardiovascular Diseases, 1977
- Total and regional cerebral blood flow measurement with 7-10-, 15-, 25-, and 50-mum microspheresJournal of Applied Physiology, 1976
- Effect of stimulation of carotid chemoreceptors on total and regional cerebral blood flow.Circulation Research, 1976
- Three dimensional geometry of acutely ischemic myocardium.Circulation, 1975
- Total and Regional Myocardial Blood Flow Measurements with 25µ, 15µ, 9µ, and Filtered 1-10µ Diameter Microspheres and Antipyrine in Dogs and SheepCirculation Research, 1974
- Polarographic evaluation of transmural oxygen availability in intact muscular arteriesJournal of Atherosclerosis Research, 1968
- The Circulation of the Fetus in UteroCirculation Research, 1967
- Structural Basis for the Static Mechanical Properties of the Aortic MediaCirculation Research, 1964
- Pathology of Pulseless DiseaseAngiology, 1963
- Intimal vascularisation and atherosclerosisThe Journal of Pathology and Bacteriology, 1951