Systematic and random errors in compression testing of trabecular bone
- 1 January 1997
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 15 (1) , 101-110
- https://doi.org/10.1002/jor.1100150115
Abstract
We sought to quantify the systematic and random errors associated with-artifacts in the platens compression test for trabecular bone. Our hypothesis was that while errors may depend on anatomic site, they do not depend on apparent density and therefore have substantial random components. Trabecular bone specimens were first tested nondestructively using newly developed accurate protocols and then were tested again using the platens compression test. Percentage differences in modulus between the techniques (bovine) proximal tibia [n = 18] and humerus [n = 17] and human lumbar spine, [n = 9] were in the range of 4-86%. These differences did not depend on anatomic site (p = 0.21) and were only weakly dependent on apparent density and specimen aspect ratio (r2 < 0.10). The mean percentage difference in modulus was 32.6% representing the systematic component of the end-artifact error. Neglecting the minor variations explained by density and specimen size (approximately 10%), an upper bound on the random error from end-artifacts in this experiment was taken as the SD of the modulus difference (±18.2%). Based on a synthesis of data taken from this study and from the literature, we concluded that the systematic underestimation error in the platens compression test can be only approximated and is in the range of 20-40%; the substantial random error (±12.5%) confounds correction, particularly when the sample size is small. These errors should be considered when interpreting results from the platens test, and more accurate testing techniques should be used when such errors are not acceptable.Keywords
This publication has 20 references indexed in Scilit:
- Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulusPublished by Elsevier ,2004
- Trabecular bone exhibits fully linear elastic behavior and yields at low strainsJournal of Biomechanics, 1994
- Femoral prosthesis implantation induces changes in bone stress that depend on the extent of porous coatingJournal of Orthopaedic Research, 1994
- Effects of specimen load-bearing and free surface layers on the compressive mechanical properties of cellular materialsJournal of Biomechanics, 1994
- Validation of an automated method of three-dimensional finite element modelling of boneJournal of Biomedical Engineering, 1993
- Theoretical analysis of the experimental artifact in trabecular bone compressive modulusJournal of Biomechanics, 1993
- Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplastyJournal of Orthopaedic Research, 1992
- The effect of specimen geometry on the mechanical behaviour of trabecular bone specimensJournal of Biomechanics, 1992
- Fracture Prediction for the Proximal Femur Using Finite Element Models: Part II—Nonlinear AnalysisJournal of Biomechanical Engineering, 1991
- Elastic properties of cancellous bone: Measurement by an ultrasonic techniqueJournal of Biomechanics, 1987