Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries
Open Access
- 1 March 2000
- Vol. 83 (3) , 338-345
- https://doi.org/10.1136/heart.83.3.338
Abstract
OBJECTIVE To improve the biocompatibility of stents using a phosphorylcholine coated stent as a form of biomimicry. INTERVENTIONS Implantation of phosphorylcholine coated (n = 20) and non-coated (n = 21) stents was performed in the coronary arteries of 25 pigs. The animals were killed after five days (n = 6), four weeks (n = 7), and 12 weeks (n = 8), and the vessels harvested for histology, scanning electron microscopy, and morphometry. MAIN OUTCOME MEASURES Stent performance was assessed by studying early endothelialisation, neointima formation, and vessel wall reaction to the synthetic coating. RESULTS Stent thrombosis did not occur in either group. Morphometry showed no significant differences between the two study groups at any time point. At five days both the coated and non-coated stents were equally well endothelialised (91% v92%, respectively). At four and 12 weeks there was no difference in intimal thickness between the coated and non-coated stents. Up to 12 weeks postimplant the phosphorylcholine coating was still discernible in the stent strut voids, and did not appear to elicit an adverse inflammatory response. CONCLUSION In this animal model the phosphorylcholine coating showed excellent blood and tissue compatibility, unlike a number of other polymers tested in a similar setting. Given that the coating was present up to 12 weeks postimplant with no adverse tissue reaction, it may be a potential candidate polymer for local drug delivery.Keywords
This publication has 30 references indexed in Scilit:
- Phosphorylcholine-Coated Metallic Stents in Rabbit Iliac and Porcine Coronary ArteriesScandinavian Cardiovascular Journal, 1998
- Subacute Stent Thrombosis and the Anticoagulation Controversy: Changes in Drug Therapy, Operator Technique, and the Impact of Intravascular UltrasoundThe American Journal of Cardiology, 1996
- Local methylprednisolone inhibition of foreign body response to coated intracoronary stentsCoronary Artery Disease, 1996
- Biocompatibility of polymer-coated oversized metallic stents implanted in normal porcine coronary arteriesAtherosclerosis, 1995
- Kinetics of drugs delivery to the arteriall wall via polyurethane‐coated removable nitinol stent: Comparative study of two drugsCatheterization and Cardiovascular Diagnosis, 1995
- Surface modification of polymers for medical applicationsBiomaterials, 1994
- Biocompatible Surfaces Using Methacryloylphosphorylcholine Laurylmethacrylate CopolymerAsaio Journal, 1994
- Phosphatidylcholine-coated chest tubes improve drainage after open heart operationThe Annals of Thoracic Surgery, 1993
- Coagulation Patterns in Bovine Left Heart Bypass with Phospholipid Versus Heparin Surface CoatingAsaio Journal, 1993
- Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.Circulation, 1985