Hotting-up the complement-fixation test
- 1 February 1983
- journal article
- research article
- Published by Cambridge University Press (CUP) in Epidemiology and Infection
- Vol. 90 (1) , 127-134
- https://doi.org/10.1017/s0022172400063920
Abstract
SUMMARY: A detailed investigation into the effect of modifying the incubation temperature of the complement-fixation (CF) test is described. For varicella-zoster virus cytomegalovirus and rubella virus, increasing the incubation temperature progressively increased the sensitivity of the CF test to reach a maximum at 15°C, at which temperature the geometric mean titre of seropositive samples was significantly greater than that found at 4°C. For these three viruses, each serum shown to contain IgG antibodies by ultrasensitive radioimmunoassay procedures was detected by CF following incubation at 15°C. No false-positive reactions occurred at 15°C, but it was our impression that anticomplementary activity was enhanced at this temperature. Significant increases in antibody titre at 15°C were also seen when measles virus, respiratory syncytial virus, adenovirus and Mycoplasma pneumoniae were employed as CF antigens. The results demonstrate that the CF test should be performed at 15°C if optimum sensitivity is to be achieved. The ability of the test to detect significant rises in antibody titre was not impaired at the higher incubation temperature.This publication has 10 references indexed in Scilit:
- The development and evaluation of a solid-phase radioimmunoassay (RIA) procedure for the determination of susceptibility to varicellaJournal of Virological Methods, 1981
- A PROSPECTIVE STUDY OF PRIMARY CYTOMEGALOVIRUS INFECTION IN PREGNANT WOMENBJOG: An International Journal of Obstetrics and Gynaecology, 1980
- EVALUATION OF A RADIOIMMUNOASSAY FOR IGM-CLASS ANTIBODIES AGAINST CYTOMEGALO-VIRUS1980
- A comparison of three tests for rubella antibody screening.Journal of Clinical Pathology, 1979
- A comparison of complement fixation, indirect immunofluorescence for viral late antigens, and anti-complement immunofluorescence tests for the detection of cytomegalovirus specific serum antibodies.Journal of Clinical Pathology, 1978
- Experiences with solid-phase “radioimmunoassay” in the rapid diagnosis of hepatitis BJournal of Medical Virology, 1978
- Technique of complementfixation test applicable to the diagnosis of virus diseases.1962
- Application of a Microtechnique to Viral Serological InvestigationsThe Journal of Immunology, 1962
- Comparative evaluation of several complement fixation techniques for laboratory diagnosis of the rickettsioses.1951