Geometrical optimization of a phased array coil for high‐resolution MR imaging of the carotid arteries
Open Access
- 17 July 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 50 (2) , 439-443
- https://doi.org/10.1002/mrm.10526
Abstract
The geometry of an RF phased‐array receiving coil for high‐resolution MRI of the carotid artery, particularly the bifurcation, was optimized with respect to signal‐to‐noise ratio (SNR). A simulation tool was developed to determine homogeneity, sensitivity, and SNR for a given imaging situation. The algorithm takes into account the coil geometry, the parameters of the measured object, and the imaging parameters of the pulse sequence. The coil with the optimum geometry was implemented as a receive‐only coil for 1.5 T and comparative SNR measurements with different coils were performed. The experimental SNR measurements verified the simulations. The optimized carotid artery phased array offered the best SNR over the desired field of view. In vivo high‐resolution MRI of the carotid arteries of healthy volunteers and patients with known stenosis was conducted with the optimized phased array coil. The capability of the phased array coil for resolving components within the carotid artery walls is demonstrated. Magn Reson Med 50:439–443, 2003.Keywords
This publication has 11 references indexed in Scilit:
- Radio-frequency Coil Selection for MR Imaging of the Brain and Skull BaseRadiology, 2001
- Clinical Imaging of the High-Risk or Vulnerable Atherosclerotic PlaqueCirculation Research, 2001
- A comparison of two methods for measuring the signal to noise ratio on MR imagesPhysics in Medicine & Biology, 1999
- Measurement of Atherosclerotic Carotid Plaque Size In Vivo Using High Resolution Magnetic Resonance ImagingCirculation, 1998
- Characterization of atherosclerotic plaques at the carotid bifurcation: correlation of high-resolution MR imaging with histologic analysis--preliminary study.RadioGraphics, 1997
- Surface coil phased arrays for high‐resolution imaging of the carotid arteriesJournal of Magnetic Resonance Imaging, 1996
- Phased‐Array Magnetic Resonance Imaging of the Carotid Artery Bifurcation: Preliminary Results in Healthy Volunteers and a Patient with Aherosclerotic DiseaseJournal of Magnetic Resonance Imaging, 1995
- Calculation of the signal-to-noise ratio for simple surface coils and arrays of coils [magnetic resonance imaging]IEEE Transactions on Biomedical Engineering, 1995
- The NMR phased arrayMagnetic Resonance in Medicine, 1990
- Comparison of linear and circular polarization for magnetic resonance imagingJournal of Magnetic Resonance (1969), 1985