In-water calibration of PDR192Ir brachytherapy sources with an NE2571 ionization chamber
- 1 August 1998
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 43 (8) , 2095-2107
- https://doi.org/10.1088/0031-9155/43/8/008
Abstract
An ionometric calibration procedure for PDR brachytherapy sources in terms of dose rate to water is presented. The calibration of the source is performed directly in a water phantom at short distances (1.0, 2.5 and 5.0 cm) using an NE2571 Farmer type ion chamber. To convert the measured air-kerma rate in water to dose rate to water a conversion factor (CF) was calculated by adapting the medium-energy x-ray dosimetry protocol for a point source geometry (diverging beam). The obtained CF was verified using two different methods. Firstly, the CF was calculated by Monte Carlo simulations, where the source-ionization chamber geometry was modelled accurately. In a second method, a combination of Monte Carlo simulations and measurements of the air-kerma rate in water (at 1.0, 2.5 and 5.0 cm distance) and in air (1 m distance) was used to determine the CF. The obtained CFs were also compared with conversion factors calculated with the adapted dosimetry protocol for high-energy photons introduced by Tölli. All calculations were done for a Gammamed PDR source-NE2571 chamber geometry. The conversion factors obtained with the four different methods agree to within 1% at the three distances of interest. We obtained the following values (medium-energy x-ray protocol): CF(1 cm) = 1.458; CF(2.5 cm) = 1.162; CF(5.0 cm) = 1.112 (% for the three distances of interest). The obtained results were checked with TLD measurements. The values of the specific dose rate constant and the radial dose function calculated in this work are in accordance with the literature data.Keywords
This publication has 16 references indexed in Scilit:
- Correction factors for water‐proofing sleeves in kilovoltage x‐ray beamsMedical Physics, 1997
- Monte Carlo calculation of dose rate distributions around wiresMedical Physics, 1997
- Dose calculation in brachytherapy for a source using a primary and scatter dose separation techniquePhysics in Medicine & Biology, 1996
- Experimental validation of Monte Carlo dose calculations about a high-intensity Ir-192 source for pulsed dose-rate brachytherapyMedical Physics, 1995
- Calibration of low activity192Ir brachytherapy sources in terms of reference air kerma rate with large volume spherical ionization chambersPhysics in Medicine & Biology, 1992
- Nuclear data sheets for A = 192Nuclear Data Sheets, 1991
- Correction factors for thick-walled ionisation chambers in point-source photon beamsPhysics in Medicine & Biology, 1990
- Effect of Finite Size of Ionization Chambers on Measurements of Small Photon SourcesRadiation Research, 1960