Diffusion-Weighted Imaging of Cerebral Infarctions: Are Higher b Values Better?
- 1 July 2002
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 26 (4) , 622-627
- https://doi.org/10.1097/00004728-200207000-00026
Abstract
The purpose of this work is to determine whether high -value ( = 3,000 s/mm ) diffusion-weighted (DW) imaging is superior to low -value ( = 1,000 s/mm ) DW imaging for the detection of cerebral infarctions older than 6 h. Echo planar DW imaging was performed at 1.5 T in 26 consecutive patients (mean age 66 years) referred for clinical diagnosis of definite acute/subacute cerebral infarction (6 h to 14 days old). The DW imaging sequences were performed using matched parameters (TR = 10,000 ms, TE (eff)= 97 ms, FOV = 24 cm, 128 x 192 matrix, slice = 5 mm, NEX = 2) with values of 1,000 and 3,000 s/mm. Areas of infarction were compared visually by two experienced neuroradiologists. Quantitative measures of MR signal and noise levels in the infarcted areas compared with contralateral normal brain were also obtained. The median time after infarction was 2.5 days (range 10 h to 14 days). By visual inspection, all infarctions were reliably identified on both the = 1,000 and the = 3,000 images. The gross signal ratio (infarct/normal brain) was approximately 33% higher in the = 3,000 images, but the = 3,000 images were rated as noticeably "noisier" by both observers in every case. This visual observation was confirmed quantitatively: The signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were 70% and 51% higher in the = 1,000 than the = 3,000 images (p < 0.0005 for both). For the evaluation of late acute/subacute cerebral infarctions, high -value ( = 3,000 s/mm(2) ) DW imaging offers no apparent diagnostic advantages compared with = 1,000 images and is significantly inferior in terms of SNR and CNR.Keywords
This publication has 17 references indexed in Scilit:
- High b-Value Diffusion-Weighted MRI of Normal BrainJournal of Computer Assisted Tomography, 2001
- Highly diffusion‐sensitized MRI of brain: Dissociation of gray and white matterMagnetic Resonance in Medicine, 2001
- Diffusion-weighted MR imaging in acute stroke: theoretic considerations and clinical applications.American Journal of Roentgenology, 1999
- Cerebral infarction: time course of signal intensity changes on diffusion-weighted MR images.American Journal of Roentgenology, 1998
- Clinical utility of diffusion‐weighted magnetic resonance imaging in the assessment of ischemic strokeAnnals of Neurology, 1997
- Hyperacute stroke: evaluation with combined multisection diffusion-weighted and hemodynamically weighted echo-planar MR imaging.Radiology, 1996
- Acute human stroke studied by whole brain echo planar diffusion‐weighted magnetic resonance imagingAnnals of Neurology, 1995
- Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.Radiology, 1988
- MR imaging technology: maximizing the signal-to-noise ratio from a single tissue.Radiology, 1985
- Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field GradientThe Journal of Chemical Physics, 1965