Magnetic Resonance Image-Guided Transcatheter Closure of Atrial Septal Defects
- 7 January 2003
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 107 (1) , 132-138
- https://doi.org/10.1161/01.cir.0000039343.95540.cf
Abstract
Background— Recent developments in cardiac MRI have extended the potential spectrum of diagnostic and interventional applications. The purpose of this study was to test the ability of MRI to perform transcatheter closures of secundum type atrial septal defects (ASD) and to assess ASD size and changes in right cardiac chamber volumes in the same investigation. Methods and Results— In 7 domestic swine (body weight, 38±13 kg), an ASD (Q p :Q s =1.7±0.2) was created percutaneously by balloon dilation of the fossa ovalis. The ASD was imaged and sized by both conventional radiography and MRI. High-resolution MRI of the ASD diameters correlated well with postmortem examination ( r =0.97). Under real-time MR fluoroscopy, the introducer sheath was tracked toward the left atrium with the use of novel miniature MR guide wires. The defect was then closed with an Amplatzer Septal Occluder. In all animals, it was possible to track and interactively control the position of the guide wire within the vessels and the heart, including the successful deployment of the Amplatzer Septal Occluder. Right atrial and ventricular volumes were calculated before and after the intervention by using cine-MRI. Both volumes were found to be significantly reduced after ASD closure ( P Conclusions— These in vivo studies demonstrate that catheter tracking and ASD device closure can be performed under real-time MRI guidance with the use of intravascular antenna guide wires. High-resolution imaging allows accurate determination of ASD size before the intervention, and immediate treatment effects such as changes in right cardiac volumes can also be measured.Keywords
This publication has 19 references indexed in Scilit:
- Editorial: Transcatheter closure of atrial septal defectsThe Journal of Thoracic and Cardiovascular Surgery, 2000
- Real-Time Magnetic Resonance Imaging: Diagnostic and Interventional ApplicationsPediatric Cardiology, 2000
- Coronary pressure measurements: catheter induced errorsHeart, 1999
- A new technique for sizing of atrial septal defectsCatheterization and Cardiovascular Interventions, 1999
- Real‐time interactive MRI on a conventional scannerMagnetic Resonance in Medicine, 1997
- Intravascular magnetic resonance imaging using a loopless catheter antennaMagnetic Resonance in Medicine, 1997
- Visualization of dedicated catheters using fast scanning techniques with potential for MR‐guided vascular interventionsMagnetic Resonance in Medicine, 1996
- High resolution intravascular MRI and MRS by using a catheter receiver coilMagnetic Resonance in Medicine, 1996
- Magnetic Deflection Forces from Atrial Septal Defect and Patent Ductus Arteriosus-Occluding Devices, Stents, and Coils Used in Pediatric-Aged PatientsThe American Journal of Cardiology, 1996
- Assessment of intracardiac shunts with gadolinium-enhanced ultrafast MR imaging.Radiology, 1992