Impedance cardiographyThe impact of new technology
Open Access
- 1 July 1998
- journal article
- review article
- Published by Wiley in Anaesthesia
- Vol. 53 (7) , 677-684
- https://doi.org/10.1046/j.1365-2044.1998.437-az0550.x
Abstract
The 1990s have witnessed major advances in impedance cardiography technology. Problems existed with the methods used to calculate cardiac output. Excessive lung fluid, as often found in critically ill patients, may also invalidate measurements. The signal processing and measurement techniques used in older systems were deficient. The newer systems, of which there are at least six, incorporate novel and improved signal processing techniques. They also offer analog visual displays, personal computer interfacing, sophisticated analytical software and haemodynamic patient management systems. Evaluation of these systems is difficult because no true ‘gold standard’ method of cardiac output measurement exists. When compared with thermodilution techniques, limits of agreement of ± 20–30% seem acceptable. These limits can be achieved in normal subjects but not in critically ill patients. Validation data are available for only half of the new systems. Until recently, the main application for impedance cardiography has been research but improved accuracy should lead to increased clinical usage.Keywords
This publication has 36 references indexed in Scilit:
- Comparison of impedance cardiography with indirect fick (CO2) method of measuring cardiac output in healthy children during exerciseThe American Journal of Cardiology, 1996
- Cardiac output measurement: Lack of agreement between thermodilution and thoracic electric bioimpedance in two clinical settingsJournal of Clinical Anesthesia, 1995
- Multicenter trial of a new thoracic electrical bioimpedance device for cardiac output estimationCritical Care Medicine, 1994
- Thoracic electrical bioimpedance measurement of cardiac output and cardiovascular responses to the induction of anaesthesia and to laryngoscopy and intubationAnaesthesia, 1992
- Esophageal electrodes allow precise assessment of cardiac output by bioimpedanceCritical Care Medicine, 1992
- Bioimpedance versus thermodilution cardiac output measurement: The bomed NCCOM3 after coronary bypass surgeryIntensive Care Medicine, 1991
- Determination of cardiac output during positive endexpiratory pressure—Noninvasive electrical bioimpedance compared with standard thermodilutionCritical Care Medicine, 1990
- Noninvasive Cardiac Output: Simultaneous Comparison of Two Different Methods with ThermodilutionAnesthesiology, 1990
- Effects of intermittent positive-pressure ventilation on cardiac output measurements by thermodilutionCritical Care Medicine, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986