Brain biopsy sampling by using prospective stereotaxis and a trajectory guide
- 1 January 2001
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 94 (1) , 67-71
- https://doi.org/10.3171/jns.2001.94.1.0067
Abstract
The authors describe their initial results obtained using a skull-mounted trajectory guide for intraoperative magnetic resonance (MR) imaging-guided brain biopsy sampling. The device was used in conjunction with a new methodology known as prospective stereotaxis for surgical trajectory alignment. Between January 1999 and March 2000, 38 patients underwent 40 brain biopsy procedures in which prospective stereotaxis was performed with the trajectory guide in a short-bore 1.5-tesla MR imager. In most cases, orthogonal T2-weighted half-Fourier acquisition single-shot turbo spin-echo (HASTE) images were used to determine the desired trajectory and align the device. The surgical trajectory was defined as a line connecting three points: the target, pivot, and alignment stem points. In all cases, surgical specimens were submitted for frozen section and pathological examination. Postoperative turbofluid-attenuated inversion-recovery and gradient-echo images were obtained to exclude the presence of hemorrhage. Trajectory determination and alignment was simple and efficient, requiring less than 5 minutes. Confirmatory HASTE images were obtained along the biopsy needle as it was being advanced or after reaching the target. All biopsy procedures yielded diagnostic tissue. One patient with a lesion near the motor strip experienced a transient hemiparesis of the hand related to passage of the biopsy needle, and another sustained a fatal postoperative myocardial infarction. No patient suffered a clinically significant or radiologically visible hemorrhage. In combination with prospective stereotaxis, the trajectory guide provided a safe and accurate way to perform brain biopsy procedures.Keywords
This publication has 15 references indexed in Scilit:
- Safety, Efficacy, and Functionality of High-field Strength Interventional Magnetic Resonance Imaging for NeurosurgeryNeurosurgery, 2000
- Navigus Trajectory GuideNeurosurgery, 2000
- A New Artifact-free Device for Frameless, Magnetic Resonance Imaging-guided Stereotactic ProceduresNeurosurgery, 2000
- A New Artifact-free Device for Frameless, Magnetic Resonance Imaging-guided Stereotactic ProceduresNeurosurgery, 2000
- Stereotactic Surgery: What Is Past Is PrologueNeurosurgery, 2000
- A mobile high-field magnetic resonance system for neurosurgeryJournal of Neurosurgery, 1999
- Comparison of Stereotactic Brain Biopsy to Interventional Magnetic-Resonance-Imaging-Guided Brain BiopsyStereotactic and Functional Neurosurgery, 1999
- Intraoperative Diagnostic and Interventional Magnetic Resonance Imaging in NeurosurgeryNeurosurgery, 1997
- Complications of CT-guided stereotactic biopsy of intra-axial brain lesionsJournal of Neurosurgery, 1994
- Targeted Brain BiopsyNeurosurgery, 1993