Impact of hemodialysis on dual X-ray absorptiometry, bioelectrical impedance measurements, and anthropometry
- 1 January 1996
- journal article
- research article
- Published by Elsevier in The American Journal of Clinical Nutrition
- Vol. 63 (1) , 80-86
- https://doi.org/10.1093/ajcn/63.1.80
Abstract
Dual X-ray absorptiometry (DXA) performs noninvasive assessment of bone and soft tissue with high precision. However, soft tissue algorithms assume that 73.2% of the lean body mass is water, a potential source of error in fluid retention. We evaluated DXA (model QDR-2000; Hologic Inc, Waltham, MA), bioelectrical impedance analysis (BIA), and simple anthropometry in 19 patients (9 women and 10 men, mean age 46 y) before and after hemodialysis, removing 0.9-4.3 L (x: 2.8L) of ultrafiltrate. The reduction in fat-free mass (FFM) measured by DXA was highly correlated with the ultrafiltrate, as determined by the reduction in gravimetric weight (r = 0.975, P < 0.0001; SEE: 233 g), whereas BIA was considerably less accurate in assessing FFM reductions (r = 0.66, P < 0.01; SEE: 757 g). Lumbar bone mineral density (BMD) was unaffected by dialysis, as were whole-body fat and BMD. Whole-body bone mineral content, however, was estimated to be 0.6% lower after dialysis. None of the simple anthropometric measurements correlated significantly with the reduction in FFM. In an unmodified clinical setting, DXA appears to be superior to other simple noninvasive methods for determining body composition, particularly when the emphasis is on repeated measurements.Keywords
This publication has 22 references indexed in Scilit:
- Precision and accuracy of measurements of whole-body bone mineral: comparisons between Hologic, Lunar and Norland dual-energy X-ray absorptiometersThe British Journal of Radiology, 1994
- Body composition in active acromegaly during treatment with octreotide: a double‐blind, placebo‐controlled cross‐over studyClinical Endocrinology, 1994
- Dual X-ray absorptiometry: a comparison between fan beam and pencil beam scansThe British Journal of Radiology, 1993
- Impact of hydration status on body composition as measured by dual energy X-ray absorptiometry in normal volunteers and patients on haemodialysisThe British Journal of Radiology, 1992
- Longitudinal precision of dual-energy X-ray absorptiometry in a multicenter studyJournal of Bone and Mineral Research, 1991
- Influence of fat on bone measurements with dual-energy absorptiometryBone and Mineral, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Fluid Volume Changes During Hemodialysis Monitored with the Impedance TechniqueArtificial Organs, 1985
- Total body bone mineral and lean body mass by dual-photon absorptiometryCalcified Tissue International, 1981
- Correlation of whole-body impedance with total body water volume.Journal of Applied Physiology, 1969