Fluospheres for Cardiovascular Phenotyping Genetically Modified Mice
- 1 September 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cardiovascular Pharmacology
- Vol. 36 (3) , 396-404
- https://doi.org/10.1097/00005344-200009000-00017
Abstract
Assessment of systemic and regional hemodynamic phenotypes in genetically engineered mice by nonradioactive methods is yet an unsolved problem. We therefore investigated whether the reference sample method using fluorescent microspheres (FMs), already validated in rats, might be used for this purpose in C57BL/6 and in apolipoprotein E (ApoE)-deficient mice. FMs were injected into the left ventricle of instrumented anesthetized mice. In 10-week-old C57BL/6, cardiac output was 18-19 ml/min, and its regional distribution under basal conditions was ∼1.5% (brain), 3.5% (heart), 9.1% (left kidney), 9.8% (right kidney), 1% (spleen), and 0.8% (stomach) (i.e., values similar to those previously reported with radioactive microspheres). Proper mixing of FMs was achieved as both kidneys had identical flows; distribution of two differently labeled FMs injected simultaneously was shown to be identical by an agreement study, and FM trapping in the capillary bed was demonstrated both histologically and by the recovery in the lungs of 90% of intravenously injected FMs. In addition, identical values for cardiac output and its distribution were obtained in different age-matched groups of C57BL/6. The FM technique also proved to be able to evidence angiotensin II and isoprenaline classic systemic and regional hemodynamic effects. Finally, applied to 30-week-old ApoE-deficient mice and age-matched C57BL/6, the FM technique showed no major hemodynamic difference between the two groups, except for coronary blood flow, which was significantly decreased in ApoE-deficient mice. In conclusion, we demonstrated for the first time the feasibility, accuracy, and reliability of the FM technique at characterizing the cardiovascular phenotype of genetically engineered mice.Keywords
This publication has 12 references indexed in Scilit:
- Blood flow distributions by microsphere deposition methodsCardiovascular Research, 2000
- MHC class II molecules, cathepsins, and La/SSB proteins in lacrimal acinar cell endomembranesAmerican Journal of Physiology-Cell Physiology, 1999
- Systemic and Regional Hemodynamics Assessment in Rats with Fluorescent MicrospheresJournal of Cardiovascular Pharmacology, 1999
- Voltage-dependent potentiation of neuronal L-type calcium channels due to state-dependent phosphorylationAmerican Journal of Physiology-Cell Physiology, 1995
- Developments in non-radioactive microsphere techniques for blood flow measurementCardiovascular Research, 1994
- Validation of fluorescent-labeled microspheres for measurement of regional organ perfusionJournal of Applied Physiology, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Simultaneous measurement of cardiac output and its distribution with microspheres in the ratCardiovascular Research, 1976
- Reference sample method for cardiac output and regional blood flow determinations in the ratJournal of Applied Physiology, 1976
- Measure- ment of distribution of cardiac outputJournal of Applied Physiology, 1968