Plow quantitation with echo‐planar phase‐contrast velocity mapping: In vitro and in vivo evaluation
- 1 November 1995
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 5 (6) , 656-662
- https://doi.org/10.1002/jmri.1880050607
Abstract
We present a multishot echo-planar imaging (EPI) phase-contrast implementation for flow quantitation. The measurement accuracy of this technique was evaluated in vitro and in vivo. A gated eight-shot EPI phase-contrast sequence (TR/TE = 16/7.4, 45° flip angle), with a flow-phase interval of 32 msec and an in-plane resolution of 2× 2 mm was initially evaluated in a pulsatile flow phantom. Subsequently, EPI phase-contrast flow measurements of the ascending and descending aorta, obtained in 10 volunteers, were compared with flow volume data acquired with a conventional cine phase-contrast sequence (TR/TE = 24/7, 45° flip angle, 48-msec flow-phase interval, 2 × 1 mm in-plane resolution). Comparisons between flow measurements were made using data obtained with the flow probe and cine phase contrast as the standard of reference for in vitro and in vivo measurements, respectively. EPI phase-contrast sequences reduced data acquisition times tenfold compared with cine phase-contrast sequences. EPI phase-contrast flow measurements correlated were with phantom flow (r = 0.98, slope = 1.1) as well as with aortic cine phase-contrast flow volume determinations (r = 0.98). A 95% confidence interval of measurement differences between echo-planar and cine phase-contrast imaging, ranging from 2.0 to - 1058 mL/min was computed. Ultrafast phase-contrast flow measurements are possible. Multishot EPI phase-contrast imaging provides high measurement accuracy in pulsatile vessels while keeping the image acquisition interval short enough to be accomplished in a comfortable breath-hold.Keywords
This publication has 28 references indexed in Scilit:
- Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggeringMagnetic Resonance in Medicine, 1994
- Interleaved echo planar flow quantitationMagnetic Resonance in Medicine, 1994
- Interleaved echo planar phase contrast angiographyMagnetic Resonance in Medicine, 1994
- Volumetric flow rates in the portal venous system: measurement with cine phase-contrast MR imaging.American Journal of Roentgenology, 1993
- Analysis of flow effects in echo‐planar imagingJournal of Magnetic Resonance Imaging, 1992
- Visualization and quantification of the human blood flow by magnetic resonance imagingJournal of Biomechanics, 1992
- Theoretical aspects of motion sensitivity and compensation in echo‐planar imagingJournal of Magnetic Resonance Imaging, 1991
- Real-time flow measurements using echo-planar imagingMagnetic Resonance in Medicine, 1991
- Quantitative flow measurements on phantoms and on blood vessels with MRMagnetic Resonance in Medicine, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986