Comparison of the flashlamp pulsed dye laser with the argon tunable dye laser with robotized handpiece for facial telangiectasia
- 1 January 1993
- journal article
- research article
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 13 (3) , 374-378
- https://doi.org/10.1002/lsm.1900130315
Abstract
This prospective study compares the efficacy, side effects, and patient acceptance of the flashlamp pulsed dye laser (FPDL) with the argon tunable dye laser with robotized handpiece (ATDL/H) for facial telangiectasias. Seventeen adult patients with bilaterally symmetric facial telangiectasias were enrolled. The right cheek on each patient was treated in one session with the FPDL at a fluence of 6.0–6.75 J/cm2 and a spot size of 5 mm. The left cheek was treated at the same session with the ATDL/H at a power of 1 W, a fluence of 26–27 J/cm2, and a hexagonal treatment area of 13 mm (127 individual 1 mm spots grouped mechanically by the handpiece). Patients were evaluated subjectively and by the investigators at 2, 4, and 6 weeks for blistering, swelling, bruising, changes in pigment, scarring, overall efficacy, and patient preference. Average treatment times were 5.4 minutes for FPDL and 9.4 minutes for ATDL/H. Blistering, crusting, and discomfort were completely resolved on both sides by week 2 in all patients. Bruising occurred in all patients with FPDL but had resolved in 62.5% of patients at 2 weeks and 100% at 4 weeks. There was no bruising with ATDL/H. Postinflammatory hyper‐pigmentation was much more prominent with FPDL but had resolved in 88% of cases by week 6. As rated by the investigators 100% of the FPDL treated areas showed excellent clearing of telangiectasias, compared with 47% of ATDL/H treated areas. Despite better efficacy of the FPDL in clearing facial telangiectasias in one treatment, of the 15 patients with a preference 47% preferred the ATDL/H due to the marked bruising experienced with the FPDL. In conclusion, although the FPDL showed greater objective efficacy, the acceptable efficacy combined with the lack of bruising led almost half of the patients to prefer treatment with the ATDL/H.Keywords
This publication has 6 references indexed in Scilit:
- Comparison of the flashlamp pulsed dye laser with the argon tunable dye laser with robotized handpiece for facial telangiectasiaLasers in Surgery and Medicine, 1993
- Treatment of Facial Vascular Lesions with a 100-µ Spot 577-nm Pulsed Continuous Wave Dye LaserAnnals of Plastic Surgery, 1989
- Comparative study of the “point‐by‐point technique” and the “scanning technique” for laser treatment of port‐wine stainLasers in Surgery and Medicine, 1989
- Tunable Pulsed Dye Laser for the Treatment of Benign Cutaneous Vascular EctasiaDermatology, 1987
- Comparative Histological Studies of the Tunable Dye (at 577 nm) Laser and Argon Laser: The Specific Vascular Effects of the Dye LaserJournal of Investigative Dermatology, 1981
- Microvasculature Can Be Selectively Damaged Using Dye Lasers: A Basic Theory and Experimental Evidence in Human SkinLasers in Surgery and Medicine, 1981