Atrial Fibrillation Ablation with Esophageal Cooling with a Cooled Water‐Irrigated Intraesophageal Balloon: A Pilot Study
- 13 December 2006
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 18 (2) , 145-150
- https://doi.org/10.1111/j.1540-8167.2006.00693.x
Abstract
A left atrioesophageal fistula is an uncommon but devastating complication that may occur during atrial fibrillation (AF) ablation, and may be due to thermal injury occurring during the radiofrequency (RF) ablation. We examined the feasibility of an esophageal cooling (ECO) method using a cooled water-irrigated intraesophageal balloon (IB). Eight patients with drug-refractory AF underwent RF catheter ablation to encircle the ipsilateral pulmonary veins. During the RF ablation at the posterior left atrium, the esophageal lumen was cooled using a 9-Fr. IB catheter with a balloon length of 40 mm and diameter of 10 mm, in which cooled water, with a water temperature of 4.5 +/- 3.1 degrees C, was irrigated while the luminal esophageal temperature (LET) was measured with an intraesophageal probe placed at a site close to the tip of the ablation catheter. In the control, the LET increased from 36.4 +/- 0.8 degrees C to 40.5 +/- 1.7 degrees C within 26.1 +/- 8.2 seconds during 3.9 +/- 1.2 RF energy applications, whereas with the ECO the LET decreased to 30.2 +/- 2.9 degrees C at baseline (P<0.01 vs control), and increased only to 33.5 +/- 2.9 degrees C (P<0.01 vs control) at most, within 30 seconds during 3.9 +/- 1.2 RF energy applications. All pulmonary veins were successfully isolated in all patients without any complications. During a follow-up period of 3.1 +/- 1.2 months, no esophageal injuries were observed and all but one patient have been free from any symptoms. Use of an IB successfully lowers LET. This might have the potential of preventing esophageal injury, although further study is required.Keywords
This publication has 20 references indexed in Scilit:
- Complications of Catheter Ablation for Atrial Fibrillation: Incidence and PredictorsJournal of Cardiovascular Electrophysiology, 2008
- Electrophysiologic and Anatomic Characterization of Sites Resistant to Electrical Isolation During Circumferential Pulmonary Vein Ablation for Atrial Fibrillation: A Prospective StudyJournal of Cardiovascular Electrophysiology, 2007
- Real‐Time Monitoring of Luminal Esophageal Temperature During Left Atrial Radiofrequency Catheter Ablation for Atrial Fibrillation: Observations About Esophageal Heating During Ablation at the Pulmonary Vein Ostia and Posterior Left AtriumJournal of Cardiovascular Electrophysiology, 2006
- A cooled intraesophageal balloon to prevent thermal injury during endocardial surgical radiofrequency ablation of the left atrium: a finite element studyPhysics in Medicine & Biology, 2005
- Discrepancies Between Catheter Tip and Tissue Temperature in Cooled-Tip AblationCirculation, 2005
- Spectral Analysis Identifies Sites of High-Frequency Activity Maintaining Atrial Fibrillation in HumansCirculation, 2005
- Acute Pyloric Spasm and Gastric HypomotilityJournal of the American College of Cardiology, 2005
- Left Atrial-Esophageal Fistula Complicating Radiofrequency Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2005
- Atrio-Esophageal Fistula as a Complication of Percutaneous Transcatheter Ablation of Atrial FibrillationCirculation, 2004
- Esophageal perforation during left atrial radiofrequency ablation: is the risk too high?The Journal of Thoracic and Cardiovascular Surgery, 2003