Abstract
Echo planar imaging (EPI) is an MRI technique of particular value to neuroscience, with its use for virtually all functional MRI (fMRI) and diffusion imaging of fiber connections in the human brain. EPI generates a single 2D image in a fraction of a second; however, it requires 2–3 seconds to acquire multi-slice whole brain coverage for fMRI and even longer for diffusion imaging. Here we report on a large reduction in EPI whole brain scan time at 3 and 7 Tesla, without significantly sacrificing spatial resolution, and while gaining functional sensitivity. The multiplexed-EPI (M-EPI) pulse sequence combines two forms of multiplexing: temporal multiplexing (m) utilizing simultaneous echo refocused (SIR) EPI and spatial multiplexing (n) with multibanded RF pulses (MB) to achieve m×n images in an EPI echo train instead of the normal single image. This resulted in an unprecedented reduction in EPI scan time for whole brain fMRI performed at 3 Tesla, permitting TRs of 400 ms and 800 ms compared to a more conventional 2.5 sec TR, and 2–4 times reductions in scan time for HARDI imaging of neuronal fibertracks. The simultaneous SE refocusing of SIR imaging at 7 Tesla advantageously reduced SAR by using fewer RF refocusing pulses and by shifting fat signal out of the image plane so that fat suppression pulses were not required. In preliminary studies of resting state functional networks identified through independent component analysis, the 6-fold higher sampling rate increased the peak functional sensitivity by 60%. The novel M-EPI pulse sequence resulted in a significantly increased temporal resolution for whole brain fMRI, and as such, this new methodology can be used for studying non-stationarity in networks and generally for expanding and enriching the functional information.Keywords
This publication has 62 references indexed in Scilit:
- Three dimensional echo-planar imaging at 7 TeslaNeuroImage, 2010
- Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRIMagnetic Resonance in Medicine, 2010
- Correspondence of the brain's functional architecture during activation and restProceedings of the National Academy of Sciences, 2009
- Distinct patterns of brain activity in young carriers of the APOE -ε4 alleleProceedings of the National Academy of Sciences, 2009
- Efficient fat suppression by slice‐selection gradient reversal in twice‐refocused diffusion encodingMagnetic Resonance in Medicine, 2008
- High-field fMRI unveils orientation columns in humansProceedings of the National Academy of Sciences, 2008
- The effect of respiration variations on independent component analysis results of resting state functional connectivityHuman Brain Mapping, 2008
- Diffusion spectrum magnetic resonance imaging (DSI) tractography of crossing fibersPublished by Elsevier ,2008
- Fast algorithms for GS-model-based image reconstruction in data-sharing fourier imagingIEEE Transactions on Medical Imaging, 2003
- Echo-volumar imagingMagnetic Resonance Materials in Physics, Biology and Medicine, 1994