Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRI
Top Cited Papers
Open Access
- 23 April 2010
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (5) , 1144-1153
- https://doi.org/10.1002/mrm.22361
Abstract
Parallel imaging in the form of multiband radiofrequency excitation, together with reduced k‐space coverage in the phase‐encode direction, was applied to human gradient echo functional MRI at 7 T for increased volumetric coverage and concurrent high spatial and temporal resolution. Echo planar imaging with simultaneous acquisition of four coronal slices separated by 44mm and simultaneous 4‐fold phase‐encoding undersampling, resulting in 16‐fold acceleration and up to 16‐fold maximal aliasing, was investigated. Task/stimulus‐induced signal changes and temporal signal behavior under basal conditions were comparable for multiband and standard single‐band excitation and longer pulse repetition times. Robust, whole‐brain functional mapping at 7 T, with 2 × 2 × 2mm3 (pulse repetition time 1.25 sec) and 1 × 1 × 2mm3 (pulse repetition time 1.5 sec) resolutions, covering fields of view of 256 × 256 × 176mm3 and 192 × 172 × 176mm3, respectively, was demonstrated with current gradient performance. Magn Reson Med 63:1144–1153, 2010.Keywords
This publication has 31 references indexed in Scilit:
- High-field fMRI unveils orientation columns in humansProceedings of the National Academy of Sciences, 2008
- Robust detection of ocular dominance columns in humans using Hahn Spin Echo BOLD functional MRI at 7 TeslaNeuroImage, 2007
- 2D‐GRAPPA‐operator for faster 3D parallel MRIMagnetic Resonance in Medicine, 2006
- Accelerated parallel imaging for functional imaging of the human brainNMR in Biomedicine, 2006
- Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA)Magnetic Resonance in Medicine, 2006
- Simultaneous phase correction and SENSE reconstruction for navigated multi‐shot DWI with non‐cartesian k‐space samplingMagnetic Resonance in Medicine, 2005
- Parallel imaging performance as a function of field strength—An experimental investigation using electrodynamic scalingMagnetic Resonance in Medicine, 2004
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Localized echo-volume imaging methods for functional MRIJournal of Magnetic Resonance Imaging, 1997