Comparative estimation of anterior chamber depth by ultrasonography, Orbscan II, and IOLMaster
- 1 June 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 30 (6) , 1268-1271
- https://doi.org/10.1016/j.jcrs.2003.11.053
Abstract
Purpose: To assess the degree of agreement of anterior chamber depth (ACD) measurements by 2 optical devices (Orbscan II and IOLMaster) and compare them with contact ultrasound A-scan. Setting: Department of Ophthalmology at Hull Royal Infirmary, England. Methods: In this prospective study of 81 eyes of 41 consecutive patients, ACD estimation was done by 3 methods—scanning slit topography (Orbscan II), partial coherence interferometry (IOLMaster), and contact ultrasound A-scan in that order. The same observer performed all measurements. Repeated measures Analysis of Variance (ANOVA) was used to analyze difference between ACD measurements by the 3 methods. Difference in measurements between methods was assessed using the paired t test. Results: The mean ACD (±SD) by the 3 methods was 3.32 mm (0.60), 3.33 mm (0.61), and 2.87 mm (0.55), respectively. There was a statistically significant difference between measurements recorded by the 3 methods ( P <.01). Mean contact A-scan measurements were 0.40 mm and 0.43 mm lower than by Orbscan II and IOLMaster respectively ( P <.01). Conclusion: Applanation ultrasound gives consistently lower measurements for ACD compared to Orbscan II and IOLMaster. Although a high degree of agreement between Orbscan II and IOLMaster was noted, further studies are needed to assess the interchangeability of measurements in clinical practice.Keywords
This publication has 12 references indexed in Scilit:
- Prediction of pseudo-phakic anterior chamber depth from pre-operative dataActa Ophthalmologica, 2009
- Anterior chamber depth measurement: A-scan versus optical methodsJournal of Cataract & Refractive Surgery, 2002
- Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliabilityJournal of Cataract & Refractive Surgery, 2001
- Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implantBritish Journal of Ophthalmology, 2000
- Phakic anterior chamber lenses for the correction of myopiaOphthalmology, 1999
- High precision biometry of pseudophakic eyes using partial coherence interferometryJournal of Cataract & Refractive Surgery, 1998
- Measuring anterior chamber depth with the Orbscan Topography SystemJournal of Cataract & Refractive Surgery, 1997
- Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1997
- Refractive Power Calculations for Intraocular Lenses in the Phakic EyeAmerican Journal of Ophthalmology, 1993
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 1992