Interactive Fluorophore and Quencher Pairs for Labeling Fluorescent Nucleic Acid Hybridization Probes
- 6 November 2007
- journal article
- Published by Springer Nature in Molecular Biotechnology
- Vol. 38 (3) , 247-255
- https://doi.org/10.1007/s12033-007-9012-9
Abstract
The use of fluorescent nucleic acid hybridization probes that generate a fluorescence signal only when they bind to their target enables real-time monitoring of nucleic acid amplification assays. Real-time nucleic acid amplification assays markedly improves the ability to obtain qualitative and quantitative results. Furthermore, these assays can be carried out in sealed tubes, eliminating carryover contamination. Fluorescent nucleic acid hybridization probes are available in a wide range of different fluorophore and quencher pairs. Multiple hybridization probes, each designed for the detection of a different nucleic acid sequence and each labeled with a differently colored fluorophore, can be added to the same nucleic acid amplification reaction, enabling the development of high-throughput multiplex assays. In order to develop robust, highly sensitive and specific real-time nucleic acid amplification assays it is important to carefully select the fluorophore and quencher labels of hybridization probes. Selection criteria are based on the type of hybridization probe used in the assay, the number of targets to be detected, and the type of apparatus available to perform the assay. This article provides an overview of different aspects of choosing appropriate labels for the different types of fluorescent hybridization probes used with different types of spectrofluorometric thermal cyclers currently available.Keywords
This publication has 23 references indexed in Scilit:
- Tentacle probes: eliminating false positives without sacrificing sensitivityNucleic Acids Research, 2007
- Quencher as Leaving Group: Efficient Detection of DNA-Joining ReactionsJournal of the American Chemical Society, 2002
- HyBeaconTM probes: a new tool for DNA sequence detection and allele discriminationMolecular and Cellular Probes, 2001
- ‘Cyclicons’ as hybridization-based fluorescent primer-probes: synthesis, properties and application in real-time PCRBioorganic & Medicinal Chemistry, 2000
- Molecular Beacons: Probes that Fluoresce upon HybridizationNature Biotechnology, 1996
- Nucleobase-Specific Quenching of Fluorescent Dyes. 1. Nucleobase One-Electron Redox Potentials and Their Correlation with Static and Dynamic Quenching EfficienciesThe Journal of Physical Chemistry, 1996
- Oligonucleotides with fluorescent dyes at opposite ends provide a quenched probe system useful for detecting PCR product and nucleic acid hybridization.Genome Research, 1995
- Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification ReactionsNature Biotechnology, 1993
- Solution-phase detection of polynucleotides using interacting fluorescent labels and competitive hybridizationAnalytical Biochemistry, 1989
- Zwischenmolekulare Energiewanderung und FluoreszenzAnnalen der Physik, 1948